409-10060
Rev D
9
of 11
5.
MAINTENANCE AND INSPECTION
5.1.
Before Storing the Pump
Perform the following steps after the piston has reached the lowest position:
1. Remove the battery cartridge.
2. Disconnect the plug of the remote control cord.
NOTE
Be sure the cord is not pulled, or becomes loose or twisted.
3. Replace the receptacle cover.
4. Disconnect the coupler.
5. Re-attach the dust cap of the coupler to prevent dust from getting into the system.
5.2.
Daily Maintenance
It is recommended the pump be inspected daily by operating and maintenance personnel.
Visually check the hydraulic oil level and it's contamination through the oil gage.
If applicable, add hydraulic oil.
If contamination of the oil is observed, replace the hydraulic oil completely (approximately one liter).
ConocoPhillips Super Hydraulic Oil MV32 is recommended.
NOTE
Pump is shipped with ConocoPhillips Super Hydraulic Oil MV32 in the pump. Do NOT mix with other oils. Always completely
replace the oil if another type of oil is used.
When replacing the hydraulic oil, remove air vent (see Figure 6).
Figure 6
5.3.
Semi-Annual Maintenance
Completely replace hydraulic oil every six months (ConocoPhillips Super Hydraulic Oil MV32 is recommended).
CAUTION
NEVER use vegetable oil or brake oil with this pump.
If the tool is maintained regularly and correctly, it should provide trouble-free service. If a problem does occur,
contact the SUPPORT CENTER at the number on the bottom of page 1.
ConocoPhillips is a trademark.
Air Vent