Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: RPIP-824-00
Rev: F
Date: April 28, 2006
Page: 3 of 11
© 2005-2006 Tyco Electronics Corporation. All rights reserved.
Unless otherwise specified dimensions are in millimeters [Inches dimensions are in between brackets]
If this document is printed it becomes uncontrolled. Check for the latest revision.
Table I
. Cable Jacket and Wire Insulation Stripped Length.
RoHS Compliant
Shield Terminator
Shield Terminator
Size
A
±
0.5
[±0.002]
B
±
0.5
[±0.002]
Minimum
Overlap
3
7.0 [0.276]
6.0 [0.236]
5.5 [0.217]
5
9.0 [0.354]
8.0 [0.315]
7.0 [0.276]
6
10.0 [0.394]
9.0 [0.354]
7.5 [0.300]
7
11.0 [0.433]
10.0 [0.394]
8.5 [0.335]
9
12.0 [0.472]
11.0 [0.433]
9.0 [0.354]
11
13.0 [0.512]
12.0 [0.472]
10.0 [0.394]
B-155-XX
B-155-XX-1000
B-155-XX-35-22-5
B-155-XX-35-22-9
CWT-XX
CWT-XX-1000
CWT-XX-W122-5
CWT-XX W122-9
13
17.0 [0.670]
16.0 [0.630]
14.0 [0.551]
3, 5
7.0 [0.276]
6.0 [0.236]
5.5 [0.217]
B-155-XX-S CWT-XX-S
7, 11
9.0 [0.354]
8.0 [0.315]
7.0 [0.276]
B-155-15XX
B-155-38XX
B-155-XXXX-WX
CWT-15XX
CWT-38XX
CWT-XXXX-WX
All
12.5 [0.492]
12.5 [0.492]
9.5 [0.374]
Center Stripped
End Stripped
4.1.3 Inspection
1. Positioning: The ground lead conductor should overlap the shield minimum length specified
in Table I.
2. Heating: The solder ring shape should not be visible and a solder fillet, at least 4.5 [0.188]
long for CWT-15XX, CWT-38XX and CWT-XXXX-WX, B-155-15XX, B-155-38XX and
B-155-XXXX-WX, should be visible on one side of the lead. Lack of a solder fillet may
indicate overheating.
3. Damage: The sleeve should not be split or cut and no wire strands should poke through the
sleeve.