background image

408-35208 

Rev

 B

 

of 7

 

5.  Loosen the locking ring (Figure 5). 

6.  Adjust the contact depth locator (Figure 5) to produce crimps as shown in Figure 3 by performing test 

crimps using the procedure described in section 1.4. 

7.  Tighten the locking ring. 

Figure 5: Locator and locking ring 

 

Locking ring 

Contact depth locator 

3.4.

 

Crimping procedure 

1.  Open the tool by squeezing the tool handles until the ratchet releases (allowing the tool handles to fully 

open).  

2.  Place the contact into the tool. 

3.  Insert the stripped wire into the contact. 

4.  While holding the wire in place, depress and hold the trigger until the contact or ferrule is fully deformed 

and the tool indenters stop moving. 

5.  Release the trigger to allow the indenters to return to the resting position. 

6.  Remove the crimped contact from the tool. 

 

 

Содержание PDT-48-00

Страница 1: ...mer Service visit our website at www te com 408 35208 22 JUN 2021 Rev B Figure 1 DEUTSCH Field Maintenance Crimp Tool PDT 48 00 1 INTRODUCTION The PDT 48 00 is a Pneumatic DEUTSCH Tool version of the...

Страница 2: ...mage from the tool falling onto the operator or the floor 2 Adjust the bench mount for efficiency and ergonomics a Loosen by rotating the knob lever b Move the tool to the desired position c Lock the...

Страница 3: ...0 12 pin 12 socket 0460 202 12 0462 201 12 12 14 3 0 2 5 2 0 222 284 5 64 7 21 The contact part number ends with a two or three digit plating code This code indicates the metal with which the contact...

Страница 4: ...e the locking clip Figure 4 3 Raise and rotate the dial Figure 4 to select a wire size Minimum 22 AWG 0 35 mm Maximum 12 AWG 3 00 mm NOTE The tool must be open prior to selecting a wire size 4 Reinsta...

Страница 5: ...t depth locator 3 4 Crimping procedure 1 Open the tool by squeezing the tool handles until the ratchet releases allowing the tool handles to fully open 2 Place the contact into the tool 3 Insert the s...

Страница 6: ...s your warranty Use gage G454 Figure 6 in dial position 16 1 0 to check wear Under normal conditions this check should be performed monthly Check more often with high volume use Figure 6 Gage G454 NOT...

Страница 7: ...foot switch Figure 8 Air fittings 5 REPLACEMENT AND REPAIR If parts are damaged or worn excessively they must be replaced Order replacement parts through your TE representative You can also order part...

Отзывы: