background image

408-35208 

Rev

 B

 

of 7

 

4.2.

 

Air supply 

The air supply is 80 to 120 PSI (5.5 to 8.3 BAR) and needs filter, dryer, and regulator. Lubricator is 
recommended. Check hoses and fittings for integrity and fix leaks as required. 

The inlet port has a ¼” NPT fitting. Apply thread sealing tape or compound to avoid leakage or damage. Adjust 

1/16” hex set screw OUT

 for a hand valve or IN for a foot switch. 

Figure 8: Air fittings 

 

5.

 

REPLACEMENT AND REPAIR 

If parts are damaged or worn excessively, they must be replaced. Order replacement parts through your TE 
representative. You can also order parts by any of the following methods: 

 

Go t

TE.com

 and click the 

Shop TE

 link at the top of the page. 

 

Call 800-522-6752. 

 

Write to: 

CUSTOMER SERVICE (038-035) 
TE CONNECTIVITY CORPORATION 
PO BOX 3608 
HARRISBURG PA 17105-3608 

For customer repair services, call 800-522-6752. 

6.

 

REVISION SUMMARY 

Revisions to this instruction sheet include: 

Replaced Figure 1 with a more accurate drawing. 

 

Содержание PDT-48-00

Страница 1: ...mer Service visit our website at www te com 408 35208 22 JUN 2021 Rev B Figure 1 DEUTSCH Field Maintenance Crimp Tool PDT 48 00 1 INTRODUCTION The PDT 48 00 is a Pneumatic DEUTSCH Tool version of the...

Страница 2: ...mage from the tool falling onto the operator or the floor 2 Adjust the bench mount for efficiency and ergonomics a Loosen by rotating the knob lever b Move the tool to the desired position c Lock the...

Страница 3: ...0 12 pin 12 socket 0460 202 12 0462 201 12 12 14 3 0 2 5 2 0 222 284 5 64 7 21 The contact part number ends with a two or three digit plating code This code indicates the metal with which the contact...

Страница 4: ...e the locking clip Figure 4 3 Raise and rotate the dial Figure 4 to select a wire size Minimum 22 AWG 0 35 mm Maximum 12 AWG 3 00 mm NOTE The tool must be open prior to selecting a wire size 4 Reinsta...

Страница 5: ...t depth locator 3 4 Crimping procedure 1 Open the tool by squeezing the tool handles until the ratchet releases allowing the tool handles to fully open 2 Place the contact into the tool 3 Insert the s...

Страница 6: ...s your warranty Use gage G454 Figure 6 in dial position 16 1 0 to check wear Under normal conditions this check should be performed monthly Check more often with high volume use Figure 6 Gage G454 NOT...

Страница 7: ...foot switch Figure 8 Air fittings 5 REPLACEMENT AND REPAIR If parts are damaged or worn excessively they must be replaced Order replacement parts through your TE representative You can also order part...

Отзывы: