background image

408-35208 

Rev

 B

 

of 7

 

4.

 

MAINTENANCE AND INSPECTION 

4.1.

 

Maintenance 

 

Clean tool and remove debris regularly. 

 

Check for missing or loose hardware. 

 

Do 

not

 immerse tool in cleaners. Vacuum or wipe clean. 

 

Do 

not

 spray oil into tool to lubricate. Use in-line lubricator. 

 

Do 

not

 open tool or make repairs. Doing so voids your warranty. 

Use gage G454 (Figure 6) in dial position 16/1.0 to check wear. Under normal conditions, this check should be 
performed monthly. Check more often with high-volume use. 

Figure 6: Gage G454 

 

NOTE 

Never close the tool on gage G454. This damages the indenters and voids the warranty. Close the tool first, then insert gage 
G454. 

NOTE 

Do not use gage G454 with the HDP-400 Power Crimper. 

Figure 7: GO and NO-GO gaging 

 

Fully inserted G454 

Green end (GO) 

Gage should not insert any further 

Red end (NO-GO) 

 

 

 

Содержание PDT-48-00

Страница 1: ...mer Service visit our website at www te com 408 35208 22 JUN 2021 Rev B Figure 1 DEUTSCH Field Maintenance Crimp Tool PDT 48 00 1 INTRODUCTION The PDT 48 00 is a Pneumatic DEUTSCH Tool version of the...

Страница 2: ...mage from the tool falling onto the operator or the floor 2 Adjust the bench mount for efficiency and ergonomics a Loosen by rotating the knob lever b Move the tool to the desired position c Lock the...

Страница 3: ...0 12 pin 12 socket 0460 202 12 0462 201 12 12 14 3 0 2 5 2 0 222 284 5 64 7 21 The contact part number ends with a two or three digit plating code This code indicates the metal with which the contact...

Страница 4: ...e the locking clip Figure 4 3 Raise and rotate the dial Figure 4 to select a wire size Minimum 22 AWG 0 35 mm Maximum 12 AWG 3 00 mm NOTE The tool must be open prior to selecting a wire size 4 Reinsta...

Страница 5: ...t depth locator 3 4 Crimping procedure 1 Open the tool by squeezing the tool handles until the ratchet releases allowing the tool handles to fully open 2 Place the contact into the tool 3 Insert the s...

Страница 6: ...s your warranty Use gage G454 Figure 6 in dial position 16 1 0 to check wear Under normal conditions this check should be performed monthly Check more often with high volume use Figure 6 Gage G454 NOT...

Страница 7: ...foot switch Figure 8 Air fittings 5 REPLACEMENT AND REPAIR If parts are damaged or worn excessively they must be replaced Order replacement parts through your TE representative You can also order part...