408-35208
Rev
B
6
of 7
4.
MAINTENANCE AND INSPECTION
4.1.
Maintenance
Clean tool and remove debris regularly.
Check for missing or loose hardware.
Do
not
immerse tool in cleaners. Vacuum or wipe clean.
Do
not
spray oil into tool to lubricate. Use in-line lubricator.
Do
not
open tool or make repairs. Doing so voids your warranty.
Use gage G454 (Figure 6) in dial position 16/1.0 to check wear. Under normal conditions, this check should be
performed monthly. Check more often with high-volume use.
Figure 6: Gage G454
NOTE
Never close the tool on gage G454. This damages the indenters and voids the warranty. Close the tool first, then insert gage
G454.
NOTE
Do not use gage G454 with the HDP-400 Power Crimper.
Figure 7: GO and NO-GO gaging
1
Fully inserted G454
2
Green end (GO)
3
Gage should not insert any further
4
Red end (NO-GO)