114-1016
8
of 8
Rev
EE
6. VISUAL AID
The illustration below shows a typical application of miniature AMP-IN contacts and miniature AMP-IN 2000
contacts. This illustration should be used by production personnel to ensure a correctly applied product.
Applications which DO NOT appear correct should be inspected using the information in the preceding pages of
this specification and in the instructional material shipped with the product or tooling.
MINIATURE AMP-IN CONTACT
MINIATURE AMP-IN 2000 CONTACT
SOLDER MUST BE EVENLY FORMED
AND THERE MUST BE NO CRACKS
LOCKING LANCE MUST BE COMPLETELY
THROUGH PC BOARD HOLE
LOCKING LANCE MUST BE COMPLETELY
THROUGH PC BOARD HOLE
WIRE INSULATION SHOULD
NOT BE CRIMPED IN
STABILIZER BARREL
INSULATION STOP/POSITIVE
BOARD STOP MUST NOT BE
TERMINATED
THERE MUST BE NO DAMAGE
TO WIRE
THERE MUST BE NO DAMAGE
TO WIRE
SOLDER MUST BE EVENLY FORMED
AND THERE MUST BE NO CRACKS
CUTOFF TAB AND BURR
CAN BE VISIBLE
CUTOFF TAB AND BURR
CAN BE VISIBLE
WIRE CONDUCTORS AND INSULATION
MUST BOTH BE VISIBLE BETWEEN
WIRE BARREL AND
INSULATION BARREL
WIRE CONDUCTORS AND
INSULATION MUST BOTH BE VISIBLE
BETWEEN INSULATION BARREL AND
INSULATION STOP/POSITIVE BOARD STOP
WIRE BARREL SEAM MUST BE
CLOSED (OR CAN BE SLIGHTLY OPEN)
WITH NO WIRE STRANDS VISIBLE
WIRE BARREL SEAM MUST BE
CLOSED (OR CAN BE SLIGHTLY OPEN)
WITH NO WIRE STRANDS VISIBLE
FIGURE 10. VISUAL AID