Maintenance and Repair
7.1 Daily Maintenance
For the daily maintenance following steps has to be taken by the responsible operator:
Clean up the tool from dust, humidity and other residues by means of a clean, soft scrubber or a
lint-free cloth.
Never use rigorous or abrasive mediums to avoid damaging the tool.
All pins, pivot points and bearing surfaces must be provided with a high-quality SAE20 motor oil.
Avoid excessive lubrication.
If the hand tool is no longer required, pinching the gripper and store the hand tool dry and clean.
7.2 Periodically Maintenance
Depending on the degree of utilization an inspection of the Hand tool for AMP DUOPLUG 2.5™
should be done by an appropriate qualified personnel.
Pinching the gripper until the mechanism of the lever brace released resp. opened and let the gripper
opened.
Do not loose the gripper too fast and completely to avoid damaging the tool head‘s springs.
Check the hand tool on abrasions and damaging, in particularly in the field of the crimper and all
pivot points.
7.3 Wear and tear parts
All wear and tear parts can be replaced easily
–
Stuffer
PN 0-0578699-1
–
Stop
PN 0-0578702-1
–
Spring (Stop) PN 0-0578705-1