FSA-PLUS Switcher (Modem Version)
Technical Manual
6341 3 103-12 - 17.05.2011
Page 5
2
Selectable Services
The FSA-PLUS Switchers are designed in such a way that the following services
can be connected in accordance with the corresponding specifications of ETSI
and BellCore:
Plain Old Telephony Service (POTS)
ISDN Basic Rate,
ISDN Primary Rate,
64 kbit/s and 2 Mbit/s and 1.5 Mbit/s permanent leased line
High speed Digital Subscriber Line (HDSL)
Asymmetric Digital Subscriber Line (ADSL)
Data services, which satisfy the following boundary conditions, can also be con-
nected:
Max. connectable voltage
1
220 V
AC
/ 200 V
DC
2
Max. connectable current
1
1 A
2
Max. connectable power
1
60 W
AC
/ 30 W
DC
2
Max. bandwidth
< 60 MHz
LSA-PLUS lines are fitted without primary protection elements for the termination
of the service cable (coming and going).
1
For reasons of electrical safety in case of accidental contact, only homopolar earthed TNV sig-
nals (telecommunication network voltage) or SELV signals (safety extra low voltage) are permit-
ted in accordance with EN 60950 !
2
Passing over these limiting values leads to the destruction of the device!