114-94467
Rev. C
7
of 31
5.
REQUIREMENTS ON THE CRIMPED CONTACTS
The following terms shown below are used in this Specification, see
Conductor position
The single strands of the conductor are clamped inside the crimp area. All single strands need to be caught in
the crimp and not a single strand must remain outside the crimp.
The wire end must be fully inserted into the crimp area and must be checked via the inspection hole after crimping.
Insulation must not be inside of the crimping area, see
Figure 1
Figure 2
Figure 3