background image

408-10043

4 of 5

Rev C

8. MAINTENANCE AND INSPECTION

8.1. Daily Maintenance

1. Remove dust, moisture, and other contaminants 
with a clean, soft brush, or a clean, soft, lint-free 
cloth. DO NOT use any objects that could damage 
the dies or tool.

2. Make sure that the proper die retaining screws 
are properly secured.

3. When the tool is not in use, keep the handles 
closed to prevent objects from becoming lodged in 
the dies. Store the tool in a clean, dry area.

4. Remove all lubrication and accumulated film from 
the dies by immersing the dies in a suitable 
commercial degreaser.

8.2. Inspection

1. Close the tool handles until the ratchet releases, 
and then allow them to quickly open freely. If they 
do not open quickly and fully, the spring is defective. 
See Section 9, REPLACEMENT.

2. Inspect the crimping surfaces of the dies for 
flattened, chipped, worn, or cracked areas. If 
damage is evident, the dies must be replaced. Refer 
to Section 9, REPLACEMENT.

9. REPLACEMENT

Order replacements through your representative, or 
call 1-800-526-5142, or send a facsimile of your 
purchase order to 717-986-7605, or write to:

CUSTOMER SERVICE (038-035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105-3608

10. REVISION SUMMARY

Updated document to corporate requirements.

Added new information to table in Figure 1 and 

rearranged table