408-8678
Rev
F
8
of 11
4. Align the NO GO element and try to insert it straight into the same crimping chamber. The NO GO
element can start entry, but it must not pass completely through the crimping chamber (Figure 10).
Figure 10: NO GO element
If the crimping chamber conforms to the gage inspection, the tool is considered dimensionally correct.
Lubricate it with a
thin
coat of any good SAE 20 motor oil.
If not, return the tool to TE for further evaluation and repair. Refer to section 10, REPLACEMENT AND
REPAIR.
For additional information regarding the use of a plug gage, refer to instruction sheet