background image

408-35054 

 
 
 

Rev 

A

 

 
 
 

of 4

 

 Carefully pull additional CAN and Power/Proximity Switch cabling through the strain-relief and wire-tie 

(see Figure 6) to eliminate any tension on the new connections.  

Note

Wire-tie may be removed, if 

necessary

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 6 

 

 Plug in the CAN cable connector and insert the Power/Proximity Switch cable connections (reference 

Figure 7).  

Note

: *

Green jumper on pin 2 of P1 is pre-installed.

 

Examine cabling for any tension and, if found, increase cable slack immediately. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 7 

 Install the new motor cover and tighten (2) M4x6.0 socket head cap screws until cover is secure. 

Field installation of the APT 5 Stepper Motor Kit (PN 2335312-1) is complete. 

Strain-Relief 

Wire-Tie (Hidden from View 

                 P1 

  Red & Brown 

  Blue & Black, Green* 

       P2 
1a 

  Green 

2a 

  Black 

     CAN 
Connector 