408-35054
Rev
A
4
of 4
Carefully pull additional CAN and Power/Proximity Switch cabling through the strain-relief and wire-tie
(see Figure 6) to eliminate any tension on the new connections.
Note
:
Wire-tie may be removed, if
necessary
.
Figure 6
Plug in the CAN cable connector and insert the Power/Proximity Switch cable connections (reference
Figure 7).
Note
: *
Green jumper on pin 2 of P1 is pre-installed.
Examine cabling for any tension and, if found, increase cable slack immediately.
Figure 7
Install the new motor cover and tighten (2) M4x6.0 socket head cap screws until cover is secure.
Field installation of the APT 5 Stepper Motor Kit (PN 2335312-1) is complete.
Strain-Relief
Wire-Tie (Hidden from View
P1
1
–
Red & Brown
2
–
Blue & Black, Green*
P2
1a
–
Green
2a
–
Black
CAN