background image

408-32091 

Rev C

 

of 4

 

The ratchet is used to control the crimp height of the terminal’s wire barrel and ensures full crimping of the 
terminal. 

3.

 

CRIMPING PROCEDURE 

Refer to the table in Figure 4 and ensure compatibility between the wire, contact, and crimping tool. Wire size 
must be within the specified range for the contact. Strip the wire to the length indicated. 

Figure 2 

CAUTION 

Do NOT cut or nick the wire strands. 

The hand crimping tool must be the one designed for crimping the wire and contact. Identify the appropriate 
crimp section (according to the wire size markings on the BACK of the tool). 

Refer to Figure 3 and proceed as follows: 

1.  Hold tool so BACK (wire side) is facing you. 

2.  Make sure the ratchet is released by squeezing the tool handles and allowing them to open FULLY. 

3.  Open flip locator. Insert contact into the flip locator (make sure contact is inserted properly). 

4.  Close flip locator. 

5.  Pre-close handles up to the third ratchet tooth. Insert wire into contact. 

6.  Close the handles until the automatic ratchet releases. 

7.  Open flip locator. Take wire with contact out of locator. 

Figure 3 

4.

 

TOOL CERTIFICATION 

These instructions have been approved by TE Design, Production, and Quality Control Engineers to provide 
documented maintenance and inspection procedures. 

Insulation 

WIRE 

SIZE 

INSULATION 

DIAMETER 

0.13-0.36 mm

2

 [26-22 AWG] 

1.30-1.91 

0.20-0.56 mm

2

 [24-20 AWG] 

Conductors 

2.03-2.54 

Wire Strip 

Length Range 

Flip Locator 