EXcel4 Controller
Page 6
Part №
Cable Type
Cores
Maximum
Distance
DIGIgarde
/
DIGIgarde
Smart /
PALMgard
e
5002-0450
5002-0451
5002-0460
Belden 9730
6
150m
Belden 9503
6
150m
OS6C24/Alpha 5096/BICC H8124
6
150m
Screened Alarm Cable
8
150m
Indala
Proximity
Reader
5002-0133
5002-0137
5002-0217
5002-0218
Belden 9730
6
150 m
Belden 9503
6
60 m
OS6C24/Alpha 5096/BICC H8124
6
60 m
Screened Alarm Cable
8
Up to 30m
Dataline
Keypad
5002-0286
5002-0315
5002-0316
Belden 9729
4
140m
FBOS2P24
4
100m
OS2P22/Alpha 5902/Belden 9502
4
60m
OS4C24/Alpha 5094/BICC H8123
4
40m
RS-232
Communi
cations
7/0.2 mm 3
–
core screened cable 3
15m
RS-485*
Communi
cations
Belden 9729
4
FBOS2P24
4
OS2P22/Alpha 5902/Belden 9502
4
OS4C24/Alpha 5094/BICC H8123
4
Screened Alarm Cable
8
CAT V (screened)
Min. 2
Inputs
7/0.2mm (screened)
2
300m
Relays
7/0.2mm or 16/0.2mm (screened)
2
Depende
nt on load
and
cable
choice
* Dependent on the converter and cable type used.
When using an EX9520R converter or USB to serial converter configured to 2-wire mode, a
maximum cable length of 500m is possible. Use of an MA45 converter or USB to serial
converter configured for 4-wire mode will allow distances of up to a maximum of 1200 m
to be achieved
.
Содержание EXcel4
Страница 1: ...EXcel4 Controller User Manual UM0012 Issue 8 ...
Страница 6: ......
Страница 20: ...EXcel4 Controller Page 14 Figure 6 Suppressor ...
Страница 30: ...EXcel4 Controller Page 24 Figure 13 TCP IP Connection setup ...
Страница 34: ...EXcel4 Controller Page 28 Figure 18 Communication channels ...
Страница 51: ...EXcel4 Controller Page 45 56 0V for Door Sense and Egress 57 Door 4 Egress Input 8 2 or 3 door configuration ...