The following procedure applies to installing the cabinet assembly using either standard (P/N 06200-00066) or chemical (06200-00060) 

anchor kits. The anchor kits 

are not

 supplied with the unit, but are available from Triton.  

1.

  Carefully inspect the shipping container for any damage and report any damage 

immediately to the shipping company. Refer to the warranty information at the 

end of this manual for information about reporting shipping damage.

2.

  Remove the VersaSafe™ cabinet  from the carton by cutting the straps and 

removing the top of the box.

3.

  Remove the packing material from inside of the box.

4.

  Remove silver key from white plastic bag attached to the VersaSafe™ wrapping.

*  imPortant  *

Model  VersaSafe™  is  designed  for  INDOOR  use  only!

u

nPaCk

 V

ersa

s

afe

5.

  Remove the remainder of the box from the unit if necessary.

6.

  Remove the wrapping from the unit.

7.

  Turn the handle under the electronic lock  to open the front enclosure door. If the 

door is locked, see sidebar on this page for help in unlocking electronic lock.

8.

  Remove the packing material from inside the vault enclosure.  

9. 

The accessory box is shipped inside the cabinet enclosure. Open and inspect the 

contents. Check the contents against the enclosed packing list and report any 

missing parts to Triton. Ensure you locate the whip antenna, if wireless TDL 

Gateway modem is installed.

10.

  Remove the 4 (four) bolts and or nuts retaining the unit to the pallet.

UNLOCKING 

COMBINATION LOCKS

Electronic Lock.

 The combination of the 

lock is preset to 

1-2-3-4-5-6

. To unlock, enter 

the preset combination and check for proper 

operation. After each keypress, the lock will 

‘beep’. After the final digit has been entered, 

the lock will beep twice, and the open period 

begins. When a valid combination has been 

entered, the operator will have approximately 

3 seconds to open the lock. To open the lock, 

turn  the  outer  ring  of  the  dial  clockwise. 

After the lock is opened, the vault door may 

be opened.

Optional Kaba Lock.  

The combination of 

the lock is preset to 

5-0-2-5-5-0

. To unlock, 

spin the dial to the left until the letters “EC” 

appear on the screen. Enter the preset com-

bination. Successful entry will display “OPr” 

on the screen. Turn the dial to the right until 

the bolt retracts. After the lock is opened, the 

vault door may be opened. 

TOOLS REQUIRED

Torque wrench, adjustable to at least 60 foot pounds, adjustable crescent, or 

ratchet wrench.
Center punch (or equivalent) for marking drill holes

Hammer

3/4” (19mm) socket

Large flat screwdriver

Bubble level

7/16” socket/box wrench

Safety goggles

Hearing pro-

tection

1/4” (6mm), 1/2” (12mm), and 8/16” 

(15mm) carbide-tipped 6” masonry bits

3/4” heavy=duty electric drill 

(rotary hammer)

Back sup-

port belt

Portable vaccuum cleaner or air blower

Wire brush

Standard Anchor Kit (part no: 06200-00066)

1/2” flat washers, 1/2” x 4 1/2” sleeve-type anchor bolts, 1/2” nuts

Chemical Anchor Kit (part no: 06200-00060)

Call for ATMGurus for availability (1-888-728-6487)

Содержание Triton VersaSafe

Страница 1: ...on and Installation TDN 07103 00335 May 17 2012 Corporate Headquarters 21405 B Street Long Beach MS 39560 PHONE 800 259 6672 FAX 228 868 9445 2012 Triton All Rights Reserved TRITON logo is a registere...

Страница 2: ...Describes anchoring the cabinet using standard steel or the optional chemical anchors Anchors provided separately Power and Communication Shows cable access area power requirements and powering up th...

Страница 3: ...mizes the possibility of liquid or food spills 2 Site wiring power communication Ensure access will not be hindered by cabinet placement 3 Location of other equipment that may cause electrical electro...

Страница 4: ...ted ground Dedicated source TheVersaSafe AC power feed will be a dedicated line to which no other electrical devices are connected The VersaSafe power line will be wired for a single duplex style outl...

Страница 5: ...ess Unit shown with Bill Acceptor bracket extended En sure there is adequate room for the door to swing open DO NOT be tempted to place the cabi net on a table or other support Severe injury and equip...

Страница 6: ...6 VersaSafeTM Installation Dimensions Deep Cabinet Physical Dimensions...

Страница 7: ...nstalled 10 Remove the 4 four bolts and or nuts retaining the unit to the pallet UNLOCKING COMBINATION LOCKS Electronic Lock The combination of the lock is preset to 1 2 3 4 5 6 To unlock enter the pr...

Страница 8: ...he previous step Drill the pilot holes approximately 1 2 12 mm deep into the floor These holes will help guide the masonry bit that will be used to drill the anchor bolt holes in the next step 3 Stand...

Страница 9: ...to mounting holes Tap anchor mounts into mounting holes 4 Place a bolt into mount then place flat washer on the anchor bolt followed by a 1 2 13mm nut on top to secure Do not tighten fully allow for l...

Страница 10: ...the cabinet not to be level 2 Begin by inserting a Chem Stud capsule into one of the mounting holes Either end of the capsule may be inserted first 3 Place a washer and a nut in that order onto a chis...

Страница 11: ...dhesive to cure for the specified time see chart and important note which follows prior to applying any load to the anchors During the winter the hole temperature may be different than the room temper...

Страница 12: ...ords are not recommended 2 AC power for the terminal should come from a dedicated source with an isolated ground The unit is designed to work on an IT Isolated Terra type power system having a phase t...

Страница 13: ...board and serve as its power supply Use TY wraps to bundle cables if necessary The TDL Gateway modem will mount atop the units power supply A USB cable will provide power to the unit from the system s...

Страница 14: ...height Ensure the four 4 mounting points between the VersaSafeTM and the Plinth are secure Do not be tempt ed to use less than the four 4 pieces of hardware supplied If more than one Plinth is used en...

Страница 15: ...Appendix A Software License Agreement Compliance Emission Statements A 1...

Страница 16: ...ense to use the ATM Software but only in connection with the operation of this ATM subject to the terms and restrictions set forth in this License Agreement You are not permitted to use the ATM Softwa...

Страница 17: ...R REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAM AGES OR FOR ANY CLAIM BY ANY THIRD PARTY YOUR SOLE REMEDYAGAINSTTRITON FOR DEFECTIVE PERFORMANCE OFTHEATM SOFTWARE WILL BE LIMITED EXCL...

Страница 18: ...otection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in a...

Страница 19: ...Appendix B Warranty Service Statement B 1...

Страница 20: ...AR PURCHASE LIMITATION OF LIABILITY IN NO EVENT SHALL MANUFACTURER BE LIABLE FOR LOSS OF PROFITS OR INCIDENTAL INDIRECT SPECIAL CONSEQUENTIAL OR OTHER SIMILAR DAMAGES ARISING OUT OF ANY BREACH OF THIS...

Страница 21: ...ibutor s use of the goods or any of their parts by reason of infringement of a patent or other intellectual property right or if in Manufacturer s opinion the goods are likely to become the subject of...

Страница 22: ...code on a unit or any component thereof or any attempt to repair a unit or to repair or replace any component by anyone other than a service technician authorized by Triton shall void this warranty W...

Страница 23: ...ment is shipped Free On Board FOB Triton s facilities The organization or individual who has purchased the equipment assumes responsibility for the equipment once it leaves Triton s facilities Should...

Страница 24: ...d Therefore we will not ship primary structural parts such as a cabinet head or main cabinet body for repair in the field Triton s Technical Services Department The primary purpose of the Technical Se...

Страница 25: ...fication as a service technician or the serial number of a Triton terminal Technical support is provided during normal business hours for the life of the product When calling for help with an operatio...

Страница 26: ...B 8 Appendix B This Page Intentionally Left Blank...

Отзывы: