5. Operation with a higher-level system control: PIN G and PIN H must be disconnected
for the emergency stop functionality (see 2.2.5). This stops the plasma process. After
making sure that safe operation is possible, unlock the machine by connecting PIN G
and PIN H. To acknowledge the triggered emergency stop, PIN K and PIN E must be
connected. Also make sure that PIN K and PIN C are disconnected (no plasma
process).
Operation with an optional remote control: In emergencies, both the plasma process
and the gas supply are interrupted by pressing the emergency stop switch on the
remote control (#6). After making sure that safe operation is possible, the emergency
stop switch must be released by turning it clockwise and the error must be
acknowledged by pressing the “QUIT ERROR” button on the remote cont
rol. The
“PLASMA ON/OFF” switch must also be released. For further plasma processes, steps
3 and 4 must be repeated.
✓
The machine is switched on.