background image

 

 

 

  piezobrush PZ2 

Z63000Z2910Z1Z62 

  Operating Instructions for Handheld Device 

PZ2 - Prototypes 

Preliminary data 

 

2019-06-12 

Please read Cautions and warnings and

 

Page 13 of 17 

Important notes at the end of this document

 

9  Decommissioning 

  Press the On/Off button again. 

  Disconnect the power supply once work is complete. 

 

10  Maintenance 

10.1 Cleaning 

Only clean the outside of the plasma generator. 

  Ensure that the plasma generator is disconnected from the power supply. 

  Only clean the plasma generator with a cloth dampened in water. Do not use solvents to clean the plasma 

generator! 

 

 

Attention – Damage to device! 

Never touch the piezo component on the front side of the device with sharp-edged 
objects. This component may be damaged by improper handling. 

 

Note! 

The plasma generator with standard nozzle is not fit for the use on metal or electrically conductive 
substrate 
Such substrate may result in negative affect on the process and damage to the device. 
The treating of electrically conductive substrate is only allowed with a specially designed  
nozzle (e.g. the nearfield nozzle). 
 
Do not use the plasma generator on sensitive electrical components for it may damage these 
components. 

X

 

X

 

 

 

Содержание piezobrush PZ2

Страница 1: ...n headers and footers Please fill in the table and then change the color to white This ensures that the table disappears invisible for the customer PDF Don t change formatting when entering or pasting...

Страница 2: ...4 Technical data 8 5 Transport storage 8 6 Installation 8 7 Special Note on the operation of the plasma process 9 7 1 General description 9 7 2 Notes on the correct handling of the substrates to be t...

Страница 3: ...pliance may result in serious or fatal injury 2 1 Residual risks This device has been manufactured in accordance with the current state of the art However it is impossible to eliminate residual risks...

Страница 4: ...nd assure electromagnetic compatibility with other electrical and electronic equipment in the immediate vicinity of the system Ensure that Operating personnel have read and understood these operating...

Страница 5: ...dering code The piezobrush PZ2 handheld device can be ordered by using ordering code Z63000Z2910Z1Z62 3 2 Correct use The piezobrush PZ2 is a handheld device for generating technical plasma It is used...

Страница 6: ...e end of this document 3 4 Description of device The individual parts of the generator are shown and named in the diagram below These terms are used throughout the operating instructions No Component...

Страница 7: ...es Preliminary data 2019 06 12 Please read Cautions and warnings and Page 7 of 17 Important notes at the end of this document No Component description 8 External power plug with changeable plugs for E...

Страница 8: ...arameters see chapter 7 Treatment speed 10 20 mm s Operating conditions Air humidity 80 rel non condensing Temperature 10 40 C 50 104 F Storage conditions Air humidity 80 rel non condensing Temperatur...

Страница 9: ...assisted adhesive bonded joints Plugging and sealing Plasma induced reduction of metal surfaces Chemical free bleaching of textiles Plasma decontamination of fabric Handling of food products for qual...

Страница 10: ...Carrying out surface treatment Depending on the type and condition of your substrate pre cleaning before the plasma process can improve the overall outcome The effect of the treatment depends on the...

Страница 11: ...harge and cause skin irritations and might be slightly painful Attention Damage to device The plasma generator may be damaged if used without gas flow resulting in a lack of the cooling medium needed...

Страница 12: ...nozzle 8 4 Nearfield Nozzle The nearfield nozzle has been specially developed for the treatment of conductive substrates Caution In operation the nozzle insert can become hot Do not touch the nozzle...

Страница 13: ...rator with a cloth dampened in water Do not use solvents to clean the plasma generator Attention Damage to device Never touch the piezo component on the front side of the device with sharp edged objec...

Страница 14: ...De energize device Switch on again Piezo component broken the plasma generator is defective Contact customer service Shutdown due to overheating Allow the plasma generator to cool down Ensure that th...

Страница 15: ...at Relyon Plasma Item number Description 1000269202 Standard Nozzle 1000606802 Nearfield Nozzle 1000606701 Multigas Nozzle 1000617300 POWER ADAPTOR 15V DC 1000602100 POWER ADAPTOR 15V DC US 100062510...

Страница 16: ...bserved 4 In order to satisfy certain technical requirements some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions e g because they...

Страница 17: ...ld MiniBlue MiniCell MKD MKK MotorCap PCC PhaseCap PhaseCube PhaseMod PhiCap PowerHap PQSine PQvar SIFERRIT SIFI SIKOREL SilverCap SIMDAD SiMic SIMID SineFormer SIOV ThermoFuse WindCap are trademarks...

Отзывы: