background image

 

AN-000260

 

 

Document Number: AN-000260

 

Page 4 of 10

 

Revision: 1.0 

 

2

 

EV_MOD_CH101 EVALUATION MODULE BOARD 

 

2.1

 

PIN ASSIGNMENTS 

Table 1. EV_MOD_CH101 ZIF Connector Pin-Out 

PIN 

 

NAME 

 

DESCRIPTION 

 

 

INT

 

Interrupt output. Can be switched to input for triggering and calibration functions 

 

 

SCL

 

SCL Input. I

2

C clock input. This pin must be pulled up to VDD externally. 

 

 

SDA

 

SDA Input/Output. I

2

C data I/O. This pin must be pulled up to VDD externally. 

 

 

PROG

 

Program Enable. This pin must be pulled down to ground externally. 

 

 

RESET_N

 

Active-low reset. This pin must be pulled up to VDD externally. 

 

 

VSS

 

Power return. 

 

 

VSS

 

Power return. 

 

 

VDD

 

Power supply input. Connect to externally regulated 1.8V supply

 

 

2.2

 

ELECTRICAL SPECIFICATIONS 

Please refer to DS-000331 CH101 Datas

heet for information on the device’s electrical 

characteristics. Please note that the datasheet 

covers CH101 part numbers with different suffixes. Regardless, the electrical specifications in the datasheet still apply. 

 

2.3

 

SCHEMATIC 

Electrical connection to the EV_MOD_CH101 module is via an 8-pin 0.5 mm pitch flat flex cable (FFC) connector. Part numbers of the 
FFC connectors on the module PCB and the recommended FFC cables are shown in Table 2. The electrical schematic of the module, 
including the connector pinout and the connections to the EV_MOD_CH101 module, are shown in Figure 2-1. Note that the 0.1 

μF 

decoupling capacitor, as recommended in the CH101 datasheet, is included in the module. Consult the CH101 datasheet and 
application notes for additional information on the electrical connections and operation.  

 

Figure 2-1. EV_MOD_CH101 Schematic 

 

Содержание EV MOD CH101-01-02

Страница 1: ...cifications and information herein without notice Chirp Microsystems 2560 Ninth Street Ste 200 Berkeley CA 94710 U S A 1 510 640 8155 www chirpmicro com Document Number AN 000260 Revision 1 0 Release Date 01 27 2021 EV_MOD_CH101 01 02 Evaluation Module User Guide ...

Страница 2: ...ION HISTORY 10 Table of Figures Figure 1 1 View of EV_MOD_CH101 01 02 evaluation module with a particle ingress filter and 45 field of view acoustic housing 3 Figure 2 1 EV_MOD_CH101 Schematic 4 Figure 2 2 EV_MOD_CH101 Module Connection EV_MOD_CH101 acoustic port is facing down 5 Figure 4 1 Dimensions of the EV_MOD_CH101 01 02 assembly 7 Figure 5 1 Recommended EV_MOD_CH101 module mounting 8 Figure...

Страница 3: ...n module The module board incorporates a CH101 Ultrasonic Sensor device with an 45 field of view acoustic housing assembly a capacitor and an FPC FFC connector This evaluation module can perform pitch catch and pulse echo range finding at distances from 4 cm to 1 2m Several programming options are available for medium and short range applications Figure 1 1 View of EV_MOD_CH101 01 02 evaluation mo...

Страница 4: ...L SPECIFICATIONS Please refer to DS 000331 CH101 Datasheet for information on the device s electrical characteristics Please note that the datasheet covers CH101 part numbers with different suffixes Regardless the electrical specifications in the datasheet still apply 2 3 SCHEMATIC Electrical connection to the EV_MOD_CH101 module is via an 8 pin 0 5 mm pitch flat flex cable FFC connector Part numb...

Страница 5: ...101 Module Connection EV_MOD_CH101 acoustic port is facing down TABLE 2 RECOMMENDED FLAT FLEX CABLE AND CONNECTOR FLAT CABLE CONNECTOR TYPE Molex 503480 0800 RECOMMENDED FLAT CABLE Molex 151660073 151660094 2 4 BILL OF MATERIALS TABLE 3 BILL OF MATERIAL QUANTITY REFERENCE PART PCB FOOTPRINT MANUFACTURER MANUFACTURER PART NUMBER 1 PCB PCB NA 1 U1 CH101 01 Custom 8 Pin TDK CH101 01 1 C1 100n 6 3V 20...

Страница 6: ... 3 1 CONFIGURATION AND PROGRAMMING Please refer to the following documents for configuration and programming information AN 000154 SmartSonic Hello Chirp Hands On Document AN 000175 SonicLib Programmers Guide 3 2 OPERATION Please refer to the following documents for operating information AN 000155 CHx01 SonicLink Software Quick Start Guide AN 000180 CH101 and CH201 SmartSonic Evaluation Kit Users ...

Страница 7: ...02 UNIT Acoustic port hole 0 75 mm Maximum width 8 15 mm Module height 5 05 mm The outer dimensions of the EV_MOD_CH101 01 02 assembly are shown in Figure 4 1 The acoustic port hole has a diameter of 0 75 mm and is in the center of the front face During transducer operation the port cannot be occluded or covered Figure 4 1 Dimensions of the EV_MOD_CH101 01 02 assembly ...

Страница 8: ...maximum range at which the sensor can detect the target Large targets such as walls are much easier to detect than smaller targets Thus the associated operating range for smaller targets will be shorter The range to detect people will be affected by a variety of factors such as a person s size clothing orientation to the sensor and the sensor s field of view In general given these factors people c...

Страница 9: ... the ToF amplitude as the sensor is rotated 180 The plots are shown in both raw LSB units and normalized dB units where 0 dB corresponds to the peak amplitude recorded on axis Chirp defines the field of view FoV as the full width at half maximum FWHM of the beam pattern in other words the FoV is the range of angles over which the amplitude remains above half the peak amplitude or 6 dB When mounted...

Страница 10: ...on the infringement of patents copyrights mask work and or other intellectual property rights Certain intellectual property owned by Chirp Microsystems and described in this document is patent protected No license is granted by implication or otherwise under any patent or patent rights of Chirp Microsystems This publication supersedes and replaces all information previously supplied Trademarks tha...

Отзывы: