6. Explanation of Functions and Precautions
6-1. Input Voltage Range
Input voltage range is single phase 85-265VAC (47-63Hz) or 120-370VDC. Input voltage, which is out of
specification, might lead the product damage.
For cases where conformance to various safeties required, described as 100-240VAC (50-60Hz). Output
derating is required for input voltage less than 90VAC or less than 127VDC.
6-2. Output Voltage Adjustment Range
Output voltage is set to rated value at shipment. Output voltage can be adjusted by output voltage adjustment
trimmer (VR51). Please set output voltage within specified adjustable range.
Turning the trimmer clockwise, the output voltage will be increased. Take note when the output voltage is
increased. excessively, over voltage protection (OVP) function may trigger and voltage will be shut down.
Furthermore, when increasing the output voltage, reduce the output current as not to exceed the maximum
output power.
When the trimmer turns quickly at no load condition, the output voltage might become unstable. To maintain
the output voltage stable, flow the output current, or remove the input of the product until the output be shut
down, and then re-input. Please turn the trimmer slowly during the output voltage adjustment.
6-3. Inrush Current
Inrush current is suppressed by power thermistor for the product. Higher current will flow at higher ambient
temperature or re-input on condition. Please select input switch or external fuse carefully. The inrush
current value specified in the specification is under cold start condition (at 25
o
C).
6-4. Over Voltage Protection (OVP)
The OVP function is output shut down method and manual reset type. OVP function operates within 115-135%
of nominal output voltage.
When OVP triggered, the output will be shut down. To reset OVP, remove the input of the product for a few
minutes, and then re-input or remote control (Option) OFF/ON is required. In addition, the setting value of OVP is
fixed and not adjustable. Never apply higher
voltage externally to the output terminal to avoid the product Failure. In case of inductive load, put protective
diode in series to the output power line.
6-5. Over Current Protection (OCP)
Constant current limit with automatic recovery.
OCP function operates when the output current exceeds 105% of maximum DC output current of specification.
The outputs will be automatically recovered when the overload condition is removed. Never operate the unit
under over current or shorted conditions, which may lead unit damage. OCP setting is fixed and cannot be
adjusted externally.
8/17