INSTRUCTION MANUAL
ZWS300RC
Series
TDK-Lambda
<Page>
7-3. Output Derating according to the Input Voltage
Load (%) is percent of maximum output current value in a rated output voltage.
7-4. Mounting Method
Insert the spacer (Max
φ
8) of height more than 8mm to lift the product. And use all mounting holes for the product
installation.
(1) Mounting Holes size
4 holes
φ
3.5mm
Allowable area by metal pieces is 9mm from each PCB corners. Refer to figure below.
If the space is not enough, the specification of isolation and withstand will not be satisfied. Take the space in the product
surroundings and the upper area of components to keep enough for convection cooling.
15/17
9mm
9m
m
9m
m
9mm
9m
m
9mm
9mm
9m
m