TDK-Lambda ZWS-C Series Скачать руководство пользователя страница 3

INSTRUCTION MANUAL

ZWS10C • 15C • 30C Series

TDK-Lambda

<Page>

Note

  •

Take note that traces of sheet metal processing be left in our power supplies.

  •

When disposing product, follow disposal laws of each municipality.

  •

Published EMI (CE, RE) or immunity is the result when measured in our standard measurement conditions and 
might not satisfy specification when mounted and wired inside end-user equipment.
Use the product after sufficiently evaluating at actual end-user equipment.

  •

When exporting our products, apply for necessary permissions as required by rules and regulations of Foreign Exchange 
and Foreign Trade Control Act.

  •

Catalogue,  contents of the instruction manual may be changed without a prior notice. Refer to latest catalogue or  
instruction manual.

  •

Reproduction or reprinting the instruction manual or its portion is forbidden without our permission.

  

LONG-TERM STORAGE METHOD AND LONG-TERM STORAGE PERIOD

  

•    Please keep the product in carton box. 

  •    Please do not apply excessive vibration, shock or mechanical stress applied directly to the product. 
  •    Please keep away from direct sunlight. 
  •    For long-term storage temperature and humidity, the following conditions shall be used as a guideline : 

Temperature range : 5℃

30℃ 

Humidity range : 40%

60%RH

Please keep away from the places where temperature and humidity can change drastically.
It can cause condensation on the product or deterioration. 

 •    For long-term storage period, we recommend to use within 2 years after receiving the product.
      < Soldering and PCB mounted products : On Board, Power Module and etc >
         For products that have been received for more than 1 year, please check lead oxidation and solderability.
         In addition, SMD type products may have MSL (Moisture Sensitivity Level) provision.
         Please be sure to read the instruction manual and delivery specifications.
     < Unit type or PCB type of products : the product is used an aluminium electrolytic capacitor >
         There is tendency that the leakage current of an aluminium electrolytic capacitor may increase when stored without using  

 

       for a long time. This phenomenon can be improved by applying voltage to the aluminum electrolytic capacitor to reduce   

 

       the increased leakage current through the self-recovery effect of the electrolyte.

         For reference, before using products that have been stored for a very long time, please warm-up first for 30 minutes or   

 

   

 

      more without taking load.

     < Criterion of warm up voltage condition > 
        (1)Implementation period : 1 year or above after the delivery
        (2)Electrical continuity condition
             Input voltage : Rating
             Load : 0A
             Ambient temperature : Normal temperature
             Time : 30 minutes or more

3/17

Содержание ZWS-C Series

Страница 1: ...product We will not be held responsible after the product has been modified changed or dis assembled Do not use this product under unusual condition such as emission of smoke or abnormal smell and so...

Страница 2: ...ction When used in environment with corrosive gas hydrogen sulfide sulfur dioxide etc there is possibility that they might penetrate the product and lead to failure When used in environments where the...

Страница 3: ...ure range 5 30 Humidity range 40 60 RH Please keep away from the places where temperature and humidity can change drastically It can cause condensation on the product or deterioration For long term st...

Страница 4: ...his hole is electrically connected to terminal of CN2 The mounting surface of the spacer should be within Max 6 2mm Mounting hole hole diameter 3 5mm These holes are used for support the unit Output T...

Страница 5: ...2 5A 5 17 Line Filter Rectifier Inrush Current Limit Circuit Filter L N Rectifier Filter Input 85 265VAC V Output V Control Circuit Output Sensing Photo coupler Switching Circuit OVP Circuit OCP Circ...

Страница 6: ...int 5V 15V 115 24V 112 ZWS30C 1 OVP point 5V 24V 115 0V Vout 0V Input on Input off Input on Input off OVP point 1 Input Voltage Output Voltage OVP act on OCP act on OCP reset 0V Vout 0V Input on Input...

Страница 7: ...nput output connector housing specified by the table below Use recommended crimping tool Connector is not included with this product Refer to the following 7 17 Connector Housing and terminal Pin Term...

Страница 8: ...ation the output will not resume To reset OVP remove the input of power supply for a few minutes and then re input In addition the setting value of OVP is fixed and not adjustable Pay attention not to...

Страница 9: ...ting more than output load current And maximum reveres voltage must withstand each power supply output voltage 6 7 Isolation Test Isolation resistance between Output terminal is more than 100M at 500V...

Страница 10: ...t to 10mA output 20mA The applied voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by hi...

Страница 11: ...e the input and cool down to reset over temperature shut down and then re input Load of derating curve indicates output derating values below are based on the maximum output current value at the rated...

Страница 12: ...mponent installed to an equipment the equipment must be re evaluated and make sure to meet allowable component temperature Electrolytic capacitor allowable Max temperature 12 17 Mounting A D E F Mount...

Страница 13: ...l mounting holes for the unit installation The vibration spec is specified under this mounting condition Recommended torque for mounting screw M3 screw 0 59N m 6 0 kgf cm Mounting Holes size Allowable...

Страница 14: ...l of the equipment If not connected the conducted noise radiation noise and output noise may increase 4 For Installation in Class II end equipment terminal Earth is unnecessary to be connected to Prot...

Страница 15: ...commended torque for mounting screw M3 screw 0 59N m 6 0 kgf cm Refer to the A type and L type outline drawings for the detailed dimensions A type L type Mounting Holes size A 2 M3 tapped embossed and...

Страница 16: ...current value at input turn on Do not select the fuse according to actual input current rms values ZWS10C 1 0A ZWS15C 1 0A ZWS30C 2 5A 10 Before concluding that the unit is at fault 1 Check if the ra...

Страница 17: ...ve UKCA Marking UKCA Marking when applied to a product or packing material for a product covered by this handbook indicates compliance with the Electrical Equipment Safety Regulations Electromagnetic...

Отзывы: