7-3.
Mounting Method
7-3-1. Mounting method for standard model
Insert the spacer (Max
φ
6.2mm) of height more than 8mm to lift the unit. And use all mounting holes for the unit
installation. The vibration spec is specified under this mounting condition.
Recommended torque for mounting screw: M3 screw, 0.59N·m (6.0 kgf · cm).
■
Mounting Holes size
Allowable area by metal pieces is 6.2mm from each PCB corners. Refer to figure below.
13/17
Height more than 8.0mm
Height more than 8.0mm
ZWS10C, ZWS15C : 2 HOLES
φ
3.5mm
ZWS30C : 4 HOLES
φ
3.5mm
ZWS10C/ZWS15C
ZWS30C