PYD20 Manual
DC-DC Converter Isolated, 20W, 2x1”, PCB Mount
1. P
RODUCT
D
ESCRIPTION
The PYD20 series are board mount 20W DC-DC converters in a rugged 2 x 1 inch housing with silicone
potting. They provide a regulated and galvanically isolated output, available as either single voltage or ± dual
output voltages.
The most outstanding features of this series are the exceptionally wide input voltage range from 8.5V to
160V (18:1) and the high input/output isolation strength of 3000Vac.
The wide allowed case temperature range from -40°C to +105°C, the low heat generation, due to the high
efficiencies up to 90% and the high shock and vibration resistance thanks to the potted design make this
device suitable for nearly every situation.
Another unique feature is the compliance with the standard EN 50155, which is an international standard
covering electronic equipment used on rolling stock for railway applications. In combination with the wide
input voltage range, there are many application opportunities in this segment. Further applications for this
DC-DC converter can be found in Distributed Power Architecture (DPA), telecommunications, battery-
powered devices, measurement and laboratory equipment, devices in industrial environments, and many
other areas.
2. P
RODUCT
F
EATURES
- 2 x 1 Inch (50.8 x 25.4mm) Industry Standard Footprint
- 3000Vac Input to Output Isolation
- 8.5-160V (18:1) Wide-range Input
- Single or ± Dual Output Voltages Available
- EN 50155 Railway Compliant
- IEC 62368-1 (ICT) Approved
- High Shock and Vibration Resistance due to Potted Design
- Efficiency up to 90% and Low No-load Power Consumption
- -40 to +105°C Operating Case Temperature Range
- Remote ON/OFF Input
3. I
NTENDED
U
SE
This device is designed and manufactured as a component part to be mounted on a pc-board and to be
installed in electronic devices.
This device is intended for commercial use, such as in industrial control, process control, monitoring and
measurement equipment or the like.
Additionally, this device is also designed for equipment that is intended for use in railway rolling stock
applications according to EN 50155.
Do not use this device in equipment, where malfunctioning may cause severe personal injury or threaten
human life without additional appropriate safety devices, that are suited for the end-application.
If this device is used in a manner outside of its specification, the protection provided by the device may be
impaired.
All parameters are typical values specified at nominal input voltage, nominal output load, 25°C ambient and after a 5 minutes run-in time unless
otherwise noted. The information presented in this document is believed to be accurate and reliable and may change without notice.
For additional information, please visit
https://product.tdk.com/en/power/py
.
2/17
DOC-ID: 260921 – Issue 1