INSTRUCTION MANUAL

 

 

7. The life expectancy 

The life of the power supply depends on the life of the built-in aluminum electrolytic capacitor. 
The life is described in reliability data. 
The life of the aluminum electrolytic capacitor varies depending on the method of mounting the power supply, the 
load current, and the ambient temperature. 
Please refer to "Electrolytic Capacitor Lifetime". 
Please do not use the product which passed over the life expectancy. 
There is a risk of unexpected output shutdown and specifications may not be satisfied. 
Please contact us for maintenance or exchange the product which passed over the life expectancy. 

 
 

8. External Fuse Rating 

Refer to the following fuse rating when selecting the external input fuse.   
Surge current flows when input turn on. Use slow-blow fuse or time-lug fuse.Fast-blow fuse can not be used.   
Fuse rating is specified by inrush current value at input turn on.   
Do not select the fuse according to actual input current (rms.) values. 

 

 

 

     

HWS30A/ME-100A/ME 

  3.15A 

   

    HWS150A/ME 

 

 

  5A 

 
 

9. Before concluding that the unit is at fault… 

Before concluding that the unit is at fault, make the following checks. 

(1)

 

  Check if the rated input voltage is connected. 

(2)

 

  Check if the wiring of input and output is correct. 

(3)

 

  Check if the wire size is not too thin. 

(4)

 

  Check if the output voltage control (V.ADJ) is properly adjusted. 

(5)

 

  Check if the 

remote sensing terminal

 is not opened. 

The output will rise and OVP may be triggered

(6)

 

  Check if the output current and output power does not over specification. 

(7)

 

  Audible noise can be heard when input voltage waveform is not sinusoidal wave. 

(8)

 

  Audible noise can be heard during Dynamic-Load operation. 

(9)

 

  Ensure that a large capacitor is not connected on the output side.   

Please use within maximum capacitance shown below. 
If connecting more than the following capacity,conditioning is needed.Please contact us for details. 

 
 

 

 

Maximum external capacitance 

MODEL 

5V 

12V 

15V 

24V 

48V 

HWS30A/ME,HWS50A/ME 

10,000uF 

5,000uF 

2,000uF 

500uF 

HWS100A/ME,HWS150A/ME 

10,000uF 

5,000uF 

1,000uF 

 
 

10. Warranty Period

 

This product is warranted for a period of 5 years from the date of shipment. 

For damages occurring at normal operation within this warranty period, repair is free of charge. 

 
 

Содержание HWS ME Series

Страница 1: ...Output power ambient temperature and ambient humidity should be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment where condensa...

Страница 2: ...g parameters Material Group IIIb Pollution Degree 2 Overvoltage Category II Class I earthed Indoor use as part of an overall equipment such that the product is accessible to service engineers only EMC...

Страница 3: ...xygen or with nitrous oxide No 3 These products are classed as ordinary equipment according to IEC EN ES CSA60601 1 and are NOT protected against the ingress of water 4 The output circuit has not eval...

Страница 4: ...stment trimmer Output monitoring indicator Green LED All screws size is M3 5 HWS100A ME HWS150A ME V Output terminal 30A max terminal V Output terminal 30A max terminal FG Frame Ground L Input termina...

Страница 5: ...nt of noise sensitivity HWS30A ME HWS50A ME HWS100A ME HWS150A ME Basic connection Local sensing Connect S terminal to V terminal and S terminal to V terminal with the attached short pieces Short piec...

Страница 6: ...Power thermistor method so that higher current will flow at higher ambient temperature or re input condition Please select input switch and fuse carefully with the high temperature and re input the p...

Страница 7: ...e load terminal 2 Between S terminal and V terminal 3 Between S terminal and V terminal If remote sensing terminals are opened the output will rise and OVP may be triggered 4 7 Output Ripple Noise The...

Страница 8: ...he power supply output voltage higher by the amount of forward voltage drop VF of the diode 2 Please adjust the output voltage of each power supply to be the same 3 Please use within the specification...

Страница 9: ...o frame ground Some of the withstand voltage tester may generate high voltage at the matching with monolithic ceramic capacitor and may cause the unit damage So please check the waveform of test volta...

Страница 10: ...of mounting screws is 6mm 4 Recommended torque for mounting screw HWS30A ME HWS150A ME M3 screw 0 49 N m 5 0 kgf cm 5 2 Output Derating according to the Mounting Directions Recommend standard mounting...

Страница 11: ...WS30A ME HWS50A ME HWS100A ME Ta Load Mounting A B C D 10 50 100 60 60 70 40 Ta Load Mounting A Mounting B D Mounting C 10 45 100 100 100 50 100 100 86 60 70 65 58 70 40 30 30 Ta Load Mounting A Mount...

Страница 12: ...minal M3 5 Screws 1 0N m 10 2kgf cm 1 6N m 16 3kgf cm 6 8mm 0 8mm 2 piece HWS100A ME AWG12 22 Output terminal M3 5 Screws 1 0N m 10 2kgf cm 1 6N m 16 3kgf cm 8 1mm 1 0mm 1 piece 0 8mm 2 piece AWG14 22...

Страница 13: ...ME 3 15A HWS150A ME 5A 9 Before concluding that the unit is at fault Before concluding that the unit is at fault make the following checks 1 Check if the rated input voltage is connected 2 Check if t...

Отзывы: