Twist wire
2-3.
Basic Connection
(Local sensing)
2-4.
Remote sensing required
①
Connect “+S” terminal to “+V” terminal and
“-S” terminal to “
-
V” terminal with sensing
wires.
②
Connect “CNT” terminal to “TOG” terminal with
wire.
③
Connect “PV” terminal to “REF” terminal with
wire.
※
Please use attachment connector for each
connection.
※
In the following cases, the output is shut down.
When
CNT
and
TOG
is opened.
When
PV
and
REF
is
opened.
①
Connect “+S” terminal to “+” terminal of load with
sensing wire
②
Connect “-S” terminal to “
-
” terminal of load with
sensing wires.
③
Connect “CNT” terminal to “TOG” terminal with wire.
④
Connect “PV” terminal to “REF” terminal with wire.
※
The accuracy of the output voltage will deteriorate
when the sensing terminals are opened.
※
In the following cases, the output is shut down.
When
CNT
and
TOG
is opened.
When
PV
and
REF
is
opened.
Attached connector when shipping
Connecting circuit with CN01 or CN02 connector
1
3
5
7
9
11
2
4
6
8
10
12
1
3
5
7
9
11
2
4
6
8
10
12
M8 Bolts and nuts for connecting
to the load line.
(These are not attached to the
product.
)
Connector : (JST) S12B-PHDSS
Attached connector when shipping
・
Housing : (JST) PHDR-12VS
・
Contact : (JST) SPHD-001T-P0.5
1
-
2, 3
-
4, 7
-
8, 9
-
10 are shorted.
M8 Bolts and nuts for connecting
to the load line.
(These are not attached to the
product.
)
Connector : (JST) S12B-PHDSS
Remove standard attached connector, and use the harness made by the
customer.
・
Housing : (JST) PHDR-12VS
・
Contact : (JST) SPHD-001T-P0.5
2
-
”+” of load, 4
-
”-” of load should be connected.
7
-
8, 9
-
10
:
should be shorted
* Please use wire for contact and crimping tool specified by maker.
+
Red
Black
Brown
Yellow
“
-
” of load
“+” of load
+
-
-
Load
Load