TDK-Lambda HWS 1000/ME Series Скачать руководство пользователя страница 1

 

-1- 

TDK-Lambda 

HWS1000/ME Series

 

INSTRUCTION MANUAL

   

 

 

   

 

HWS 1000/ME Series

 

Instruction Manual

 

BEFORE USING THE POWER SUPPLY UNIT

 

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using 
this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. 
 

  DANGER 

·

 

Never use this product in locations where flammable gas or ignitable substances are present. 

 

  INSTALLATION WARNING

 

·

 

When installing, ensure that work is done in accordance with the instruction manual. 
When installation is improper, there is risk of electric shock and fire. 

·

 

Installation shall be done by Service personnel with necessary and appropriate technical training and experience. 
There is a risk of electric shock and fire. 

·

 

Do not cover the product with cloth or paper etc. Do not place anything flammable around. 
This might cause damage, electric shock or fire. 

 

  WARNING on USE

 

·

 

Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a burn. 

·

 

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. 

·

 

For products with no cover, do not touch them as there are high-voltage and high temperature parts inside. 
Touching them might cause injury such as electric shock or burn. 

·

 

There are cases where high voltage charge remains inside the product immediately after the input is cut off. 
Therefore, do not touch even if they are not in operation as you might get injured due to high voltage and high temperature. 
You might also get electric shock or burn. 

·

 

Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage the 
product. We will not be held responsible after the product has been modified, changed or dis-assembled. 

·

 

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. 
Please stop using it immediately and shut off the product. It might lead to fire and electric shock. In such cases, please contact us. 
Do not attempt repair by yourself, as it is dangerous for the user. 

·

 

Do not operate and store these products in environments where condensation occurs due to moisture and humidity. 
It might lead fire and electric shock. 

·

 

Do not drop or apply shock to this product. It might cause failure. Do not operate these products mechanical stress is applied. 

·

 

When necessary, this products is to be repaired only by us or our authorized agents. It is important that this product cannot be used 
in hazardous environments (facilities such as nuclear power control system or life support equipment) without our written consent. 

·

 

Do not drop or insert anything into unit. It might cause failure and fire, when using the unit under such condition. 

·

 

The outputs of these products must be earthed in the end use equipment to maintain SELV.   
If the outputs are not earthed, they must be considered hazardous and must not be made user accessible. 

 

  CAUTION on MOUNTING

 

·

 

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on. 

·

 

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, 
otherwise the product will be damaged. 

·

 

Input line, please use the wires as short and thick as possible. 

·

 

Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances and 
direct sunlight, or places where product is exposed to water or rain. 

·

 

Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly ventilated. 

·

 

Please shut down the input when connecting input and output of the product. 

·

 

When installing in environment where conductive foreign, dust and liquid may be present, please consider penetration of above 
foreign material in the power supply by installing filter, to prevent trouble or malfunction. 

·

 

This power supply is primarily designed and manufactured to use and enclose in other equipment. 

·

 

This power supply unit has a built-in fan for air-cooling. Do not block air intake and exhaust. It might cause fire. 

·

 

Do not operate and store this unit at the condition of condensation. In such case, waterproof treatment is necessary. 

DA032-04-80/ME-E 

Содержание HWS 1000/ME Series

Страница 1: ...ric shock In such cases please contact us Do not attempt repair by yourself as it is dangerous for the user Do not operate and store these products in environments where condensation occurs due to moisture and humidity It might lead fire and electric shock Do not drop or apply shock to this product It might cause failure Do not operate these products mechanical stress is applied When necessary thi...

Страница 2: ...sign such as providing protective circuit or protective device inside the system providing redundant circuit to ensure no instability when single device failure occurs When used in environments with strong electromagnetic field there is possibility of product damage due to malfunction When used in environment with corrosive gas hydrogen sulfide sulfur dioxide etc there is possibility that they mig...

Страница 3: ...e that traces of sheet metal processing be left in our power supplies When disposing product follow disposal laws of each municipality Published EMI CE RE or immunity is the result when measured in our standard measurement conditions and might not satisfy specification when mounted and wired inside end user equipment Use the product after sufficiently evaluating at actual end user equipment When e...

Страница 4: ...of this power supply unit Remote sensing lines shall be twisted or use the shielded wire Remote ON OFF control lines shall be twisted or use the shielded wire 2 1 Front Panel Explanation HWS1000 Front Panel Output terminal Output terminal ON Output Power On indication green LED The indicator turns on when the power supply output is in normal operating condition V ADJ Output voltage adjust trimmer ...

Страница 5: ...cessary 5 PC Current balance terminal For output current balancing in parallel operation 6 COM Ground for PC and PV signal 7 PV Output voltage external control terminal For power supply output voltage control with an external voltage Connect it with the terminal REF when PV function is unnecessary 8 REF Reference Voltage terminal for Output voltage control REF and PV are connected when shipping 9 ...

Страница 6: ...ng terminals are opened In the following cases the output is shut down When CNT and TOG is opened When PV and REF is opened Attached connector when shipping Connecting circuit with CN01 or CN02 connector 1 3 5 7 9 11 2 4 6 8 10 12 1 3 5 7 9 11 2 4 6 8 10 12 M8 Bolts and nuts for connecting to the load line These are not attached to the product Connector JST S12B PHDSS Attached connector when shipp...

Страница 7: ...load line These are not attached to the product Connector JST S12B PHDSS Remove standard attached connector and use the harness made by the customer Housing JST PHDR 12VS Contact JST SPHD 001T P0 5 1 2 3 4 7 8 should be shorted 9 CNT Should be connected to ON OFF control signal 10 TOG Should be connected to Signal Ground Please use wire for contact and crimping tool specified by maker M8 Bolts and...

Страница 8: ...ler Rectifier Filter Input 85 265VAC E Output CNT TOG Remote ON OFF Control S S COM PV Output Current Balance PC PF Standby supply Latch Circuit OVP Circuit UVP Circuit Low output Voltage Detection Photo coupler Delay Circuit Output Sensing Photo coupler Reference Voltage Photo coupler FAN Photo coupler REF Circuit topology Switching frequency Half Bridge converter 46kHz PFHC Circuit Active filter...

Страница 9: ...t 2 OCP ACTION OTP ACTION REMOTE OFF REMOTE OFF REMOTE OFF REMOTE OFF REMOTE ON REMOTE ON REMOTE ON REMOTE ON FAN STOP FAN ALM ACTION SHUT DOWN 5sec TYP 5sec TYP OCP Point 105 or more 3 OCP Shut down 1 Level 2 4V H 12V or Open 0V L 0 8V or Short 2 OVP Point 24V 125 145 36V 125 138 48V 115 125 3 OCP Point 24V 48V Model Input voltage AC180 265V Peak current 127 24V 48V Peak current is less than 10 s...

Страница 10: ...provided OCP function operates when the output current exceeds 105 of maximum DC output current specification and the over current or short circuit condition continues 5 second or more the output will be shut down When the OCP is triggered the input power is cut off for a few minutes and then power is re input or remote ON OFF control signal should be input for recovery of the output The OCP setti...

Страница 11: ...nput is connected The output is turned to ON when TOG and CNT terminals are shorted and output is turned to OFF when these terminals are opened When the function is not used connect TOG and CNT terminals with short piece The standards for this function are as follows TOG terminal is ground for CNT terminal The Mode of control CNT Level for TOG Terminal Output Built in Fan Motor Short or L 0 0 8V O...

Страница 12: ...ope is too long 5 10 Series Operation For series operation either method A or B is possible There might be a step in the rise waveform during series operation Note1 Please connect a diode for by pass when using method A of the series operation Please use the diode with rated forward current is equal or more than load current and that the rated maximum reverse voltage is higher than output voltage ...

Страница 13: ...wer supply to be same value within 1 or 100mV whichever is smaller 2 Use same length and type of wires for all load lines 3 Maximum value of output current in parallel is up to 80 of all paralleled models The purpose of the current balancing function is the static power up Therefore the output voltage might decrease according to the condition of dynamic load There might be a step in the rise wavef...

Страница 14: ...etween output and CNT PF shall be more than 10MW at 100VDC For safety operation voltage setting of DC isolation tester must be done before the test Ensure that it is fully discharged after the test CNT TOG PF PC S S E AC L AC N Output E chassis 500VDC 100MW or more CNT TOG PF PC S S E AC L AC N Output CNT PF 100VDC 10MW or more Isolation tester Isolation tester ...

Страница 15: ...ply may be damaged by high impulse voltage at timer switch on and off Connect input and output as follows If output is left open during test output voltage might appear momentarily This product have monolithic ceramic capacitor in secondary circuit to frame ground Some of the withstand voltage tester may generate high voltage at the matching with monolithic ceramic capacitor and may cause the unit...

Страница 16: ...m 20 to 120 at the PV voltage is from 1V to 6 0 V Note Only as for the model of 48V output the output voltage is used from 20 to 110 at the PV voltage is from 1V to 5 5V Output Voltage Derating Note Only as for the type of 48V output the maximum output voltage is used up to 110 at 90 load current Output voltage usage below 20 is not a guaranteed There is a possibility that it cannot be use with ce...

Страница 17: ... PV terminal and REF terminal is short by using standard connector supplied 2 Set the power supply output voltage to maximum value of the output voltage variable range mentioned in specification standard by adjusting V ADJ volume at the front panel 3 Remove standard connector after input is cut off 4 Connect external variable resistor 50kΩ between REF terminal and COM terminal Then connect middle ...

Страница 18: ...tivated input is temporarily cut off for a few minutes and then power is re input or remote ON OFF control signal should be input for recovery of the output Input voltage range AC180V 265V Continuous Peak output time τ Within 10 seconds Peak output current Ip Within the rated peak output current Duty up to 35 Duty x 100 Condition 1 Ip2 Irms max Condition 2 Ip12 a2 1 Irms max Ip Ip1 Irms τ T Model ...

Страница 19: ...front side and more than 50mm from rear side 3 Please note that ventilation will be worsened in a dusty environment 4 Built in fan is limited life part which require periodic replacement Replacement will be charge 5 The ambient temperature of this power supply is less than 50mm from the center of a front side 6 The maximum allowable penetration of mounting screw is 6mm 7 Recommended torque for mou...

Страница 20: ...prove noise sensitivity 4 Attaching a capacitor to the load terminals can eliminate noise 5 E terminal of this power supply is functional earthing For safety purposes connect protective earthing terminal to the mounting set ground terminal 6 Recommended torque for the terminal piece 7 Recommended wiring Recommended circuit protector AC250V20A Recommended noise filter RSEN 2020 TDK Lambda Corp Inpu...

Страница 21: ...is properly adjusted OVP might be triggered and output is cut off 6 Check if the wiring of S and S terminal is correct If in open condition the stability and the accuracy of the output deteriorate 7 If use function of the remote ON OFF control check if the remote ON OFF control connector is not opened If in open condition output is cut off 8 Check if the built in fan is not stopped Is fan stopped ...

Страница 22: ...maintenance or exchange the product which passed over the life expectancy 11 Warranty Period This product is warranted for a period of 5 years from the date of shipment For damages occurring at normal operation within this warranty period repair is free of charge 12 CE MARKING UKCA MARKING CE MARKING CE Marking when applied to a product or packing material for a product covered by this handbook in...

Отзывы: