SAFETY APPROVALS
UL 60950-1 and CSA22.2 No.60950-1 - UL Recognized. C-UL for Canada.
IEC 60950-1 - CB Report and Certificate.
EN 60950-1 - CE mark.
Marking by the CE Symbol indicates compliance to the Low Voltage Directive of the European Union.
A “Declaration of Conformity” in accordance with the preceding directives and standards has been made and is on file at our EU
representative TDK LAMBDA UK, located at Kingsley Avenue, Ilfracombe, Devon EX34 8ES, UK.
A “Declaration of Conformity” may be accessed via company website www.uk.tdk-lambda.com/technical-data
SAFETY INSTRUCTIONS
CAUTION: The following safety precaution must be observed during all phases of operation, service and repair of this equipment.
Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and
intended use of this equipment and may impair the built-in protections within. TDK Lambda shall not be liable for user’s failure to
comply with these requirements.
Vorsicht
Die folgenden Sicherheitsvorschriften müssen vor Inbetriebnahme und in jedem Betriebszustand bei Service oder Reparatur
beachtet werden. Missachtung der Sicherheitsvorschriften und Warnhinweise aus diesem Handbuch führen zur Verletzung
der bestehenden Sicherheitsstandards. Bei Betrieb des Gerätes ausserhalb dem bestimmungsgemässen Einsatz können die im
Gerät integrierten Schutzfunktionen beeinträchtigt werden. TDK-Lambda ist nicht haftbar für Schäden, die durch Missachtung
dieser Sicherheitsvorschriften entstehen können.
CAUTION: HFE1600-xy units are not authorized for use as critical component in nuclear control systems, life support systems or
equipment for use in hazardous environments without the express written approval of the managing director of TDK-Lambda.
Vorsicht
Dieses Produkt ist nicht für die Verwendung als kritische Komponente in nuklearen Steuerungssystemen, lebenserhaltenden
Systemen oder Geräte für den Einsatz in gefährlichen Umgebungen, ohne die ausdrückliche schriftliche Genehmigung durch
TDK-Lambda zugelassen
POWER SYSTEM, OVERVOLTAGE CATEGORY & ENVIRONMENTAL CONDITIONS
The HFE1600-xy units have been evaluated for using in TT and IT (230VAC line - to - line) power systems.
The HFE1600-xy units have been evaluated to Overvoltage category II.
The HFE1600-xy units intended for use in the following operation conditions:
* Indoor use
* Pollution degree 2
* Max. operational altitude: 3000m above sea level
*Ambient temperature: -10°C-50°C at 100% load, up to 70°C with output de-rating applied (refer to Specification above).
GROUNDING
HFE1600-xy units are Class I product. To minimize electrical shock hazard, the HFE1600-xy units must be connected to an electrical
ground. The instruments must be connected to the AC power supply mains through a three conductor power cable, with the
ground wire firmly connected to an electrical ground (safety ground) at the power outlet. For instruments designed to be hard-
wired to the supply mains, the protective earth terminal must be connected to the safety electrical ground before any other
connection is made. Any interruption of the protective ground conductor or disconnection of the protective earth terminal will
cause a potential shock hazard that might cause personal injury.
Erdungskonzept
Dieses Produkt ist ein Gerät der Schutzklasse 1. Zur Vermeidung von gefährlichen Energieinhalten und Spannungen, ist das
Gehäuse an eine Schutzerde anzuschliessen. Der PE-Anschluss ist an einen festen Erder anzuschliessen. Bei Festverdrahtung des
Gerätes ist sicherzustellen, dass der PE Anschluss als erstes angeklemmt wird. Jede mögliche Unterbrechung des PE-Leiters oder
Trennung der PE Verbindung kann einen möglichen elektrischen Schlag hervorrufen, der Personenschäden zur Folge hätte.
LIVE CIRCUITS
Operating personnel must not remove the HFE1600-xy unit cover.
No internal adjustment or component replacement is allowed by non-TDK Lambda qualified service personnel. Never replace
components with power cable connected. To avoid injuries, always disconnect power, discharge circuits and remove external
voltage sources before touching components.
Restricted Access Area: HFE1600-xy units should only be installed in a Restricted Access Area. Access should be available to service personnel only.
Spannungsführende Teile
Die Geräteabdeckung darf nicht durch Endanwender geöffnet werden. Interne Modifikationen, sowie Bauteileaustausch
ist nur durch TDK-Lambda qualifiziertes Personal erlaubt. Vor Austausch von Bauteilen ist das Netzkabel bzw. die
Versorgungsspannung zu trennen. Energieversorgungsanschlüsse sind immer zu trennen, um Personenschäden durch
gefährliche Energieinhalte und Spannungen auszuschliessen. Die Stromkreise sind zu entladen, externe Spannungsquellen
sind zu entfernen, bevor auf Bauteile bzw. Komponenten Ebene gearbeitet wird.