HFE1600 Series Instruction Manual

HFE1600 SERIES SPECIFICATIONS:

HFE1600-12 HFE1600-24 HFE1600-32 HFE1600-48

1

Rated output voltage

V

12

24

32

48

2

Output voltage set point

V

12±1%

24±1%

32±1%

48±1%

3

Output voltage range

V

9.6~13.2

19.2~29.0

25.6~38.4

38.4~58

4

Rated Output Current at Vin ≥ 170Vac              (*1)

A

133

67

47

33

5

Rated Output Current at 100 ≤ Vin ≤ 132Vac   (*1)

A

100

50

37.5

25

6

Rated Output Current at 85V ≤Vin < 100Vac

(*1)

A

Linear derating 1% per 1VAC from output current at 100VAC:

7

Rated output power Vin ≥ 170Vac

W

1596

1608

1500

1584

8

Rated output power 100 ≤ Vin ≤ 132Vac

W

1200

1200

1200

1200

9

Rated output power 85Vac ≤ Vin < 100Vac

W

Linear derating 1% per V

10 Input voltage / frequency range   

(*2)

 ---

85~265Vac continuous, 47~63Hz, Single phase

11 Maximum input current (115/230Vac)

A

12.4/8.1

12 Power Factor (Typ) (100/230Vac) at full load

 ---

>0.99/0.98

13 Efficiency at 75% rated load (Typ)

(*3)

%

87/90%

88/90%

88/90%

89/92%

14 Efficiency at 100% rated load (Typ)

(*3)

%

87/90%

87/90%

87/90%

88/91%

15 Inrush current                                                      

(*4)

A

Less than 35A

16 Hold-up time

mS

≥ 10mS typical at 115/230Vac input, 

rated output voltage and less than 80% of rated load.

17 Maximum line regulation

(*5)

%

0.25%

18 Max load regulation

(*6)

%

0.50%

19 Output Ripple and noise P-P       (*7) 0~+70°C

mV

240

240

320

480

-10~0°C

mV

360

360

580

780

20 Temperature stability

%

0.05% of rated Vout for 8hrs after 30min warm-up.

Constant line, load and temperature.

21 Temperature coefficient of output voltage

PPM/°C

±200

22 Remote sensing

(*8)

 ---

 Refer to instruction manual.

23 Parallel operation

(*9)

 ---

Single wire current share, 5% accuracy of rated Iout, up to 10 units 

of the same voltage and the same current rating.

24 Series operation

 ---

(with external diodes), 2 units. Refer to instruction manual.

25 Over current protection  85 ≤ Vin ≤ 132Vac

%

Minimum 105% of rated output current. 

170 ≤ Vin ≤ 265Vac

105~120% of rated output current. 

26 Over voltage protection

(*10)

V

Tracking OVP, range: 1.1xVout ,Accuracy:±3%, 

Refer to Instruction Manual.

27 Over temperature protection

 ---

Inverter shut down, automatic restart.

28 Remote On/Off control 

 ---

Two complementary inputs. By electrical signal or dry contact. 

Refer to instruction manual.

29 "DC OK" signal

(*13)

 ---

Tracking, On when Vout>90±5% of set output voltage. 

Open collector signal. Max sink current: 10 mA.

30 Over-Temperature warning

(*13)

 ---

Refer to instruction manual. 

Open collector signal. Max sink current: 10 mA.

31 "AC FAIL" signal

(*13)

 ---

 On when 85Vac<Vin<270Vac.

Open collector signal. Max sink current: 10 mA.

32 Auxiliary power supply output                                      (*11)

 ---

11.2~12.5V, 0.5A.  240mVp-p ripple and noise

33 Vout programming by external voltage

 ---

 By 0~5V, equal to Vout min ~ Vout max . Refer to Instruction Manual.

34 Vout programming by external resistor

 ---

By 1Kohm  potentiometer . Refer to Instruction Manual.

35 Front panel indicators

 ---

AC OK, DC OK/FAIL

36 I²C Interface

---

Optional, PMBus compatible. Refer to Instruction Manual.

37 Operating temperature

(*14)

 ---

-10~+50°C. 100% load.

+50°C to +60°C   Derate Output by 2%/°C.

+60°C to +70°C   Derate Output by 2.5%/°C.

38 Storage temperature

 ---

 -30~85°C   

39 Operating humidity

 ---

10~90% RH, no condensation.

40 Storage humidity

 ---

10~95% RH, no condensation.

41 Cooling

 ---

By internal Fans. Variable speed control 

based on ambient temperature and power level.

42 Vibration 

 ---

Built to meet IEC60068-2-64 (Basic Transportation)

43 Shock

 ---

Built to meet IEC60068-2-27 (Basic Transportation)

44 Conducted emission

 ---

Built to meet EN55022 Class B, FCC part 15 Class-B, VCCI Class-B

45 Radiated emission

 ---

Built to meet EN55022 Class A, FCC part 15 Class-A, VCCI Class-A

46 Immunity

 ---

Built to meet  IEC61000-4-2 (Level 2,3), -3 (Level 2), -4 (Level 2), 

-5 (Level 3,4), -6 (Level 2), -8 (Level 4), -11

47 Applicable safety standards

---

UL60950-1 Second Edition, EN60950-1 Second Edition

48 Withstand voltage

Input-Output:

 ---

3000Vrms, 1min. 

Input-Ground:

 ---

2000Vrms, 1min. 

Output - Ground:

 ---

500VAC  1min.  500VAC  1min. 500VAC  1min. 2250VDC 1min (POE)

49 Insulation resistance

 ---

More than 100MΩ at 25°C and 70% RH. Output-Ground: 500Vdc 

50 Leakage current                                               (*12)

mA

Less Than 0.75/1.5mA  at 115/230Vac range

51 Weight  (Typ)

Kg

Max. 1.55

52 Size (W*H*D)

 ---

85x41x300mm.  Refer to Outline Drawing.

1

Содержание HFE1600-48

Страница 1: ...Instruction Manual 27 Over temperature protection Inverter shut down automatic restart 28 Remote On Off control Two complementary inputs By electrical signal or dry contact Refer to instruction manual...

Страница 2: ...um output power by 5 10 Inverter shut down method Reset by recycle AC voltage or by On Off control 11 Measured with JEITA RC9131A 1 1 probe using 470 F electrolytic capacitor and 0 1 F film capacitor...

Страница 3: ...HFE 1600 12 24 48 Series HFE 1600 12 24 48 Series Fig B Output Power derating at temp 60 C Fig C Output Power derating at temp 70 C Pout 1500W 1200W 1100W 1000W Vin 85Vac All Output Voltages Fig A1 Ou...

Страница 4: ...L RETURN B14 NC B2 PS EXIST B15 DC OK B3 AUX_OUT 12V B16 NC B4 SENSE B17 NC B5 NC B18 TEMP ALARM B6 CURRENT SHARE B19 V REFERENCE OUT B7 ENABLE B20 NC B8 VOLTAGE ROGRAMMING B21 AC FAIL B9 SENSE C1 CHA...

Страница 5: ...act 0 0 6v or short SIGNAL RETURN B8 VOLTAGE PROGRAMMING Input 0 5V referenced to S Provides Vout programming by Voltage Refer to Instruction Manual Chapter 1 5 1 6 SENSE B9 SENSE Positive sense The S...

Страница 6: ...d for use in the following operation conditions Indoor use Pollution degree 2 Max operational altitude 3000m above sea level Ambient temperature 10 C 50 C at 100 load up to 70 C with output de rating...

Страница 7: ...tage fluctuations should not exceed 10 of nominal voltage HEAT HAZARD WARNING Top bottom and side surfaces may become hot when operating the unit continuously To reduce the risk of injury from a hot s...

Страница 8: ...L RETURN in order for the supply to turn on V A6 10 V A1 5 SENSE B9 SENSE B4 ENABLE B7 HFE1600 V V B1 SIGNAL RETURN LOAD Fig 1 1 1 2 FRONT PANEL INDICATORS 1 DC OK LED indicator GREEN when Output Volt...

Страница 9: ...n Voltage Trimming by potentiometer Fig 1 5 HFE1600 48 HFE1600 24 HFE1600 12 HFE1600 32 1 2 Basic configuration Remote Sense For basic configuration SENSE have to be connected to the V terminals on th...

Страница 10: ...0mA shunted by internal 24V zener isolated from Output and referenced to SIGNAL RETURN Fig 1 8 Open collector signals are shunted by internal 24V zener 1 6 OUTPUT VOLTAGE PROGRAMMING by External Volta...

Страница 11: ...ignal between the paralleled units automatic current balance is achieved with accuracy of Accuracy 10 20 Iout 50 of max Iout Up to 10 units Accuracy 5 Iout 50 of max Iout Up to 10 units Derate the tot...

Страница 12: ...of positive unit and Sense of negative unit twisted pair to Load point or to V and V accordingly for Local Sense Output Voltage can be adjusted independently for each unit Controls Monitoring signals...

Отзывы: