4-6. Low Output Detection Circuit (DCOK) 

Low output voltage detection circuit is provided. DCOK signal is only valid after AC input is turn-on for more than one 
sec. DCOK signal will turn “High” level to indicate abnormal status when the output voltage becomes less than 
approximately 80% of rated.    It uses the open collector method as shown below 
                       

 

4-7. Remote ON/OFF Control 

Remote ON/OFF control is provided. 
Using this function, output on/off is allowed to be controlled without input voltage on/off. The output is turned ON 
when CNT+ and CNT- terminals are shorted, while the output is turned OFF when these terminals are opened. When 
this function is not used, connect CNT+ and CNT- terminals together. The specifications for this function are as follows 
 
(1) TTL compatible. 
(2) The maximum input voltage to CNT+ terminal is 12V, and the maximum allowable reverse voltage is -1V. 
(3) The source current for CNT+ terminal is 3.5mA. 
(4) A switch or a relay or a transistor or a FET can be used as ON/OFF switch. 
 
The /RL option model reverses the logic of the remote ON/OFF function. 

 

Voltage Range between CNT+ and CNT- 

Output Status 

Standard type 

/RL option 

2.4 

 H 

 12.0V or Open 

OFF 

ON 

0.0 

 L 

 0.8V or Short 

ON 

OFF 

             
 

           

 

 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Содержание GWS 500 Series

Страница 1: ...and notify in the system instruction manual Never operate the unit under over current or short circuit conditions for more than 30 seconds or outside its specified Input Voltage Range which could res...

Страница 2: ...stment trimmer The output voltage rises when the trimmer is turned clockwise 8 CN201 Remote Sensing DCOK 5VSB Remote On Off and PV signals Refer to 2 2 1 blank Standard type BAT Battery charging for 2...

Страница 3: ...is output is not controlled by the remote ON OFF control 8 5V COM Return loop for 5VSB output 9 CNT Remote ON OFF control terminal When CNT is pulled to TTL low power supply unit turns ON Otherwise it...

Страница 4: ...ct S terminal to terminal of load and S terminal to terminal of load with sensing wires The total line voltage drop side line and side line shall be less than 0 3V In case that sensing lines are too l...

Страница 5: ...or use shielded wires Remote ON OFF control lines shall be twisted or use shielded wire Current for each terminal screw shall be 40A or less Basic Connection Local Sensing Connect with the attached co...

Страница 6: ...then re input Alternatively use CNT reset Remote ON OFF OFF to ON OVP setting is fixed and cannot be adjusted externally 4 4 Over Current Protection OCP OCP function operates when the output current e...

Страница 7: ...while the output is turned OFF when these terminals are opened When this function is not used connect CNT and CNT terminals together The specifications for this function are as follows 1 TTL compatibl...

Страница 8: ...A Method B 4 10 Parallel Operation A Operation to increase the Output Current is not possible B Operation as a Backup Power Supply is possible as follows 1 Set the power supply output voltage higher...

Страница 9: ...el limit output voltage variation range at 80 120 At PV voltage variation 4V 6V Connection method PV voltage Nominal Input Voltage Output Voltage Linearity 12V 24V 36V 48V 5 5V 6V 5V Nominal Vout 0 60...

Страница 10: ...elow 24 BAT should be used to charge 24V battery while 48 BAT should be used to charge 48V battery Battery charging Constant Current is applicable for valid output voltage range The unit may hiccup be...

Страница 11: ...n the specified voltage range is present 4 15 Output Dynamic Load Response During output dynamic load test from no load condition the output voltage level might experience a higher voltage dip of 15 t...

Страница 12: ...rrent limit of withstand voltage test equipment at 20mA Output chassis 100mA The applied voltage must be gradually increased from zero to testing value and then gradually decreased for shut down When...

Страница 13: ...at least 15cfm and air blowing out from the opposite side of the input output connectors 70 50 Airflow 15 cfm OUTPUT DERATING CURVE 0 20 40 60 80 100 120 25 0 25 50 75 100 Ta o C LOAD MOUNTING A B 70...

Страница 14: ...rse case temperature rise the selected measurement point should not face direct airflow and the equipment powered should operate under worse case operating conditions 1 Absolute temperature Maximum te...

Страница 15: ...terminal The recommended wire type MODEL Recommended Wire Recommended torque Recommended crimp type terminal D Max T Max Mounting Pieces Max GWS500 AWG18 10 M4 Screws 1 27 N m 13 kgf cm 6 8mm 0 8mm 4...

Страница 16: ...disconnect or turn off the AC input and let the unit cool down sufficiently before turning ON the AC input again 7 Check if the output current and output wattage does not exceed the specification 8 A...

Страница 17: ...method Standard installation Following cases will not be covered by warranty 1 Improper usage and mis handling like dropping or applying shock to the unit and defects from operation exceeding specific...

Отзывы: