* Parallel operation (Master/Slave) with Active current sharing.
* Remote sensing to compensate for voltage drop of power leads.

* Cooling fan speed control for low noise and extended fan life.
* Zero stacking- no ventillation holes at the top and bottom surface of the power supply.
* Optional GPIB interface (SCPI compatible).
* Optional Isolated Analog programming/monitoring (0-5V or 0-10V, user selectable

and 4-20mA).

The Genesys

power supplies series can be configured into a programmable power

system of up to 31 units using the built-in RS232/RS485 communication port in the power

supply and the RS485 linking cable provided with each power supply.
In a GPIB system, each power supply can be controlled using the optional GPIB controller

(factory installed).

The following parameters can be programmed via the serial communication port:
1. Output voltage setting.
2. Output current setting.
3. Output voltage measurement.
4. Output on/off control.
5. Output current measurement.
6. Foldback protection setting.
7. Over-voltage protection setting and readback.
8. Under-Voltage limit setting and readback.
9. Power-supply start up mode (last setting or safe mode)

Analog inputs and outputs are provided at the rear panel for analog control of the power
supply. The output voltage and the current limit can be programmed by analog voltage or by
resistor, and can be monitored by analog voltage. The power supply output can be remotely
set to On or Off and analog signals monitor the proper operation of the power supply and the
mode of operation (CV/CC).

Genesys

power supplies of the same output voltage and current rating can be paralleled in

master-slave configuration with automatic current sharing to increase power available.

Output connections are made to rear panel bus-bars for models up to 100V and to a 4-

terminal wire clamp connector for models above 100V rated output voltage. Either the

positive or negative terminal may be grounded or the output may be floated. Models up to

60VDC Rated Output shall not float outputs more than +/- 60VDC above/below chassis

ground. Models >60VDC Rated Output shall not float outputs more than +/-600VDC

above/below chassis ground. Contact factory for assistance with higher float voltage

applications.
Local or remote sense may be used. In remote sense, the voltage drop on the load wires

should be minimized. Refer to the specifications for the maximum voltage drop value.

* External Analog Programming and Monitoring standard (0-5V or 0-10V, user selectable).

1.2.4 Multiple output power system

1.2.5 Control via the serial communication port

1.2.6 Analog voltage programming and monitoring

1.2.7 Parallel operation

TM

TM

1.2.8 Output connections

8

1.2.9 Cooling and mechanical construction

1.3.1 General

1.3.2 Serial link cable

1.3.4 AC cables

The Genesys series is cooled by internal fans. At the installation, care must be taken to
allow free air flow into the power supply via the front panel and out of the power supply via
the rear panel. The Genesys

power supplies have a compact and lightweight package

which allows easy installation and space saving in the application equipment.

Accessories are delivered with the power supply or separately upon ordering. The list below
shows the possible accessories and ordering numbers.

S

TM

TM

1.3 ACCESSORIES

erial link cable, for linking power supplies by RS485 communication is provided with the

power supply.
Cable description: 0.5m length, shielded, RJ-45 type plugs, 8 contacts (P/N: GEN/RJ45).

* Output terminal shield

AC cables are not provided with the power supply.
Refer to Table1-1 for recommended AC input cables (customer supplied). Add a non-locking
plug approved by the national safety standards of the country of usage.

1.3.3 Misc. hardware

* Strain relief for AC cord

* DB25 plug kit (AMP, 749809-9)
* Connector plug kit, (Phoenix Contact, plug:IMC 1,5/7-ST-3,81, Header: IMC 1,5/7-G-3,81)

9

Observe all torque guidelines within this manual. Over torqueing may damage
unit or accessories. Such damage is not covered under manufacturers warranty.

CAUTION

Min 3x12AWG (2 wire plus safety ground),
stranded copper, 300V, 60 c minimum, rated for
25A. 3m max. length, outer diameter: 9~11mm.

O

Min 4x14AWG (3 wire plus safety ground),
stranded copper, 600V, 60 c minimum, rated for
15A. 3m max. length, outer diameter: 9~11mm.

O

190-240V~ , Single Phase

190-240V~ , Three Phase

AC Input Range

AC Input Cable

Table 1-1: Recommended AC input cable

9

Содержание Genesys GEN10-240

Страница 1: ...rammable DC Power Supplies 2 4kW in 1U Built in RS 232 RS 485 Interface Advanced Parallel Operation Optional Interface Compliant LAN IEEE488 2 SCPI GPIB Multi Drop Isolated Analog Programming User Man...

Страница 2: ...4 IA669 04 01 Rev D SUPPLIES USER MANUAL This Manual Covers Models GEN8 300 GEN10 240 GEN16 150 GEN20 120 GEN30 80 GEN40 60 GEN60 40 GEN80 30 GEN100 24 GEN150 16 GEN300 8 GEN600 4 IA669 04 01 Rev D IA...

Страница 3: ...us Substances Notes Concentration Values of Toxic and Hazardous Substances Elements wt Subpart Name This information sheet was prepared based on People s Republic of China Management Methods for Contr...

Страница 4: ...y 3V m EN 61000 4 4 2004 A1 2010 EFT B Power leads 2KV Signal leads 0 5KV EN 61000 4 5 2006 Conductive Surges Common mode 2KV Differential mode 1KV EN 61000 4 6 2007 Conducted Disturbances 3Vrms EN 61...

Страница 5: ...This page intentionaly left blank...

Страница 6: ...L CHARACTERISTICS 2 13 OUTLINE DRAWINGS Pg 13 3 1 GENERAL 3 2 PREPARATION FOR USE 3 3 INITIAL INSPECTION 3 4 RACK MOUNTING 3 4 1 To install the power supply in a rack 3 4 2 Rack mount slides 3 5 LOCAT...

Страница 7: ...e OVP level 5 3 2 Activated OVP protection indications 5 3 3 Resetting the OVP circuit 5 4 UNDER VOLTAGE LIMIT UVL 5 4 1 Setting the UVL level 5 5 FOLDBACK PROTECTION 5 5 1 Setting the Foldback protec...

Страница 8: ...7 3 Initialization control commands 7 7 4 ID control commands 7 7 5 Output control commands 7 7 6 Global output commands 7 7 7 Status control commands 7 8 STATUS ERROR AND SRQ REGISTERS 7 8 1 General...

Страница 9: ...This page intentionaly left blank...

Страница 10: ...ccurring as a result ofthe buyer s circuitry or the buyer s supplied products No other warranty is expressed or implied WARRANTY SERVICE This product must be returned to an authorized TDK Lambda Ltd s...

Страница 11: ...combe Devon EX34 8ES UK TM NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provid...

Страница 12: ...l cause a potential shock hazard that might cause personal injury There is a potential shock hazard at the RS232 485 and the IEEE ports when using power supplies with rated or combined voltage greater...

Страница 13: ...rminal Off Supply On Supply Direct Current DC Alternative Current AC Three PhaseAlternating Current Standby Supply The WARNING sign denotes a hazard An attention to a procedure is called Not following...

Страница 14: ...5...

Страница 15: ...6...

Страница 16: ...low the user to set the output parameters the protection levels Over Voltage protection Under Voltage limit and Foldback and preview the settings The rear panel includes the necessary connectors to co...

Страница 17: ...ply The output voltage and the current limit can be programmed by analog voltage or by resistor and can be monitored by analog voltage The power supply output can be remotely set to On or Off and anal...

Страница 18: ...J 45 type plugs 8 contacts P N GEN RJ45 Output terminal shield AC cables are not provided with the power supply Refer to Table1 1 for recommended AC input cables customer supplied Add a non locking pl...

Страница 19: ...s warm up Constant line load temperature O Less than 0 05 of rated output current over 30 minutes following load change 500 400 250 700 90 150 12 30 60 40 10 5 8 16V model Less than 0 2 of rated outpu...

Страница 20: ...ALARM FINE PREVIEW FOLDBACK REMOTE RS232 RS485 IEEE OUTPUT ON FRONT PANEL LOCK 1 Control functions 2 Display 3 Indications 2 9 ENVIRONMENTAL CONDITIONS 1 Operating temperature 2 Storage temperature 3...

Страница 21: ...faces RS232 485 IEEE Isolated Analog LAN Sense Remote Programming and Monitoring 5V d c auxiliary output are SELV Models with 60V Vout 400V Output is Hazardous communication control interfaces RS232 4...

Страница 22: ...with power supply 2 Bus bars for 8V to 100V models See detail Wire clamp connector for 150V to 600V models shown 3 AC cable strain relief supplied with power supply 4 Chassis slides GENERAL DEVICES P...

Страница 23: ...it TM TM I 3 4 1 To install the Power Supply in a rack 14 NOTE HINWEIS WARNING WARNUNG WARNUNG WARNING To avoid electric shock hazard do not insert conductive parts through the front panel slits Um di...

Страница 24: ...15...

Страница 25: ...n Trennung des Ger tes vom Netz Some components inside the power supply are at AC voltage even when the On Off switch is in the Off position To avoid electric shock hazard disconnect the line cord and...

Страница 26: ...ed as a basic incoming inspection check Refer to Fig 4 1 and Fig 4 2 for the location of the controls indicated in the procedure 1 Ensure that the power supply is configured to the default setting AC...

Страница 27: ...y Ensure that the front panel CURRENTLED is on 6 Turn off the front panelAC power switch 7 Remove the shunt from the power supply output terminals Refer to Section 5 3 for explanation of the OVPfuncti...

Страница 28: ...ges Observe proper safety procedures Turn off theAC input power before making or changing any rear panel connection Ensure that all connections are securely tightened before applying power There is a...

Страница 29: ...10 15 25 40 60 100 200A 2 3 5 8 12 20 30 50 400A 2 4 6 10 15 25 Resistivity Ohm 1000ft Maximum length in Feet to limit voltage drop to 1V or less Cross sect area mm 2 2 5 4 6 10 16 25 35 8 21 5 09 3...

Страница 30: ...a surge suppressor across the output to protect the power supply The breakdown voltage rating of the suppressor must be approximately 10 higher than the maximum output voltage of the power supply 21 E...

Страница 31: ...22...

Страница 32: ...screw B from enclosure bottom cover to release the shutter 4 Insert stripped wires into enclosure bottom cover opening and then to the terminals tighten the terminals screws securely see fig 3 8 5 Loo...

Страница 33: ...inimize noise pick up If shielded wires are used the shield should be connected to the ground at one point either at the power supply chassis or the load ground The optimal point for the shield ground...

Страница 34: ...ould be connected to the distribution terminals or at the most critical load 3 9 11 Grounding outputs Either the positive or negative output terminals can be grounded To avoid noise problems caused by...

Страница 35: ...shielded to prevent accidental contact with hazardous voltages An den Anschl ssen f r die Sense Leitungen besteht bei Stromversorgungen mit einer Nennausgangsspannung von mehr als 40V die Gefahr eines...

Страница 36: ...pply Refer to Warranty Information for further instructions 3 10 4 J2 sense connector technical information 3 11 REPACKAGING FOR SHIPMENT 0 22 0 25Nm Notes 1 If the power supply is operating in remote...

Страница 37: ...nt panel TM Fig 4 1 Front panel controls and indicators 28 1 Number Control Indicator Description Section High resolution rotary encoder for adjusting the Output Voltage Also adjusts the OVP UVL level...

Страница 38: ...play shows OUP Press again to set the UVLusing VOLTAGE encoder the current display shows UUL Main function Auxiliary function Go to local Press REM LOC to put the unit into Local REM LOC button is dis...

Страница 39: ...ower supply rear panel Refer to Table 4 2 for explanations about the rear panel connections and controls Fig 4 2 Rear panel connections and controls 8 100V Models 150 600V Models shown 1 Number Item D...

Страница 40: ...dard units shown Isolated Remote Analog programming connector for units equipped with Isolated Analog control option IEEE connector for units equipped with IEEE programming option M4 stud and hardware...

Страница 41: ...Programmed by External Resistor Rear panel Enable Disable control is active Down Factory default Output Voltage Programmed by Front Panel Output Current Limit Programmed by Front Panel 0 5V 0 5Kohm 0...

Страница 42: ...the V potential of the power supply Do not attempt to bias any of these terminals relative to the V or any other potential Use the Isolated Programming interface option to allow control from a progra...

Страница 43: ...mode indication Enable Disable the power supply output by dry contact short open with ENA_IN Input for Shut Off control of the power supply output Output for indication of the power supply status No...

Страница 44: ...oltage When the output is disabled press the PREV button and then rotate the VOLTAGE encoder knob The VOLTAGE meter will show the programmed output voltage for 5 seconds after the adjustment has been...

Страница 45: ...e the VOLTAGE encoder knob to adjust the OVP level The display will show OUP and the setting value for 5 seconds after the adjustment has been completed and then will return to it s previous state The...

Страница 46: ...ncel the Foldback protection The power supply output will be disabled and the VOLTAGE display will show OFF Press the OUTbutton to enable the power supply output 3 Turn the power supply output Off and...

Страница 47: ...a TTL signal output at J1 16 referenced to IF_COM at J1 2 3 Isolated Interface Common When a fault condition occurs PS_OK level is low with maximum sink current of 1mA when no fault condition occurs P...

Страница 48: ...shows O7P and the ALARM LED blinks Resetting the OTP circuit can be automatic non latched or manual latched depending on the Safe orAutomatic restart mode In Safe start mode the power supply stays of...

Страница 49: ...5 1 Series connection local sensing Fig 5 2 Series connection remote sensing Remote programming in series operation for increased output voltage 1 Programming by external voltage 2 Using the SO functi...

Страница 50: ...4 Programming via the Serial Communication port RS232 RS485 5 14 2 Series connection for positive and negative output voltage In this mode two units are configured as a positive and negative output S...

Страница 51: ...desired voltage Program the current limit to the desired load current limit divided by the number of parallel units During operation the master unit operates in CV mode regulating the load voltage at...

Страница 52: ...tting change refer to Sec 7 2 7 for details b The Slave units parameters will automatically set the following Output voltage to approximate 102 of rated output voltage Programmed Current to zero UVL t...

Страница 53: ...es is displayed selects that mode In this mode the front panel controls are enable to program and monitor the power supply parameters In this mode the following front panel controls are disabled VOLTA...

Страница 54: ...e Analog mode the output voltage and current limit can be programmed by analog voltage or by programming resistors via J1 contacts 9 and 10 refer to sec 6 4 and 6 5 Refer to Table 6 1 for Local Remote...

Страница 55: ...s 4 5 6 and 9 are not required for remote programming Their setting can be determined according the application 2 The control circuits allow the user to set the output voltage and current limit up to...

Страница 56: ...resistors to the mating plug of J1 as shown in Fig 6 2 7 Set the programming resistors to the desired resistance and turn the power supply ON Adjust the resistors to change the power supply output 1 S...

Страница 57: ...nitor Iout monitor Vout monitor Iout monitor Signal J1 11 J1 24 J1 11 J1 24 J1 12 J1 12 0 5V 0 10V Down Up Range SW1 4 Return J1 connection Table 6 5 Monitoring signals setting FCC requirements for ra...

Страница 58: ...REM LOC button to put the unit into Local mode 2 Press and hold for approximately 3sec the REM LOC button The VOLTAGE display will indicate the communication port address 3 Using the VOLTAGE adjust e...

Страница 59: ...o set the status registers and read them while the unit is in Local mode If the Enable registers are set refer to section 7 8 the power supply will transmit SRQ s while in Local Front panel control in...

Страница 60: ...HIELD TX RX SG SHIELD RX TX SG DB 25 CONNECTOR 8 PIN CONNECTOR REMARKS TWISTED PAIR 8 1 13 1 2 3 5 7 8 1 PIN NO HOUSING HOUSING PIN NO NAME NAME SHIELD RX TX SG SHIELD TX RX SG DB 9 CONNECTOR 8 PIN CO...

Страница 61: ...it The Address is sent separately from the command It is recommended to add a 100 msec software delay between query or sent command to next unit addressing Refer to section 7 7 3 for details The end o...

Страница 62: ...s a numeric value the value may be up to 12 characters long 4 Carriage Return If the CR character ASCII 13 is received by itself the power supply will respond with OK and CR The Genesys 2400W series c...

Страница 63: ...7 5 Output control commands 7 7 4 ID control commands Command Description Returns the power supply model identification as an string Returns the software version as an ASCII string Returns the unit s...

Страница 64: ...ting level is shown in Table 5 1 Attempting to program the OVP below this level will result in execution error response E04 The OVP setting stays unchanged 15 OVP n Returns the power supply operation...

Страница 65: ...gister FLT and STAT are updated Other registers are not changed Non Latching faults FB OVP SO are cleared OUT fault stays Sets the output voltage value in volts The range of voltage values is shown in...

Страница 66: ...ual measured current PC programmed set current SR status register 2 digit hex FR fault register 2 digit hex Example response MV 45 201 PV 45 MC 4 3257 PC 10 SR 30 FR 00 Reads Fault Conditional Registe...

Страница 67: ...mand or query received One SRQ when SEVE goes from all zeroes to any bit set Setting more SEVE bits does not cause more SRQs Positive Logic 0 No Event 1 Event Occured 7 8 STATUS ERROR AND SRQ REGISTER...

Страница 68: ...own has occurred The supply output is turned On by front panel button or OUT 1 command The supply output is turned On by front panel button or OUT 1 command The supply output is turned On by front pan...

Страница 69: ...OFF ENA Bit Set condition Bit reset condition User command FENA nn where nn is hexadecimal User command FENA nn where nn is hexadecimal if nn 00 no fault SRQs will be generated Table 7 10 Fault Event...

Страница 70: ...ommand to read the register CLS and power up also clear the Status Event Register The Fault Event Register is not cleared by RST BIT Status name Status symbol Bit Set condition Bit reset condition Cha...

Страница 71: ...ds with line feed On some PC systems pressing the number keypad Enter will distort displayed messages Use the alphabetic Enter instead Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow con...

Страница 72: ...e programming temperature coefficient Output current programming temperature coefficient Input impedance Absolute maximum voltage Max voltage between program inputs and supply outputs Output voltage m...

Страница 73: ...put Output current monitoring output Shield connected internally to chassis of the supply GND GND VMON_ISO IMON_ISO SHLD 4 5 6 7 8 Ground Ground Ground Ground Table 8 1 Detailed description of Isolate...

Страница 74: ...J1 8 and J1 12 refer toTable 4 4 3 Set setup switch SW1 1 to its UPposition for Output Voltage external programming and SW1 2 to its UPposition for Output Current limit external programming 4 Set SW1...

Страница 75: ...on for Output Current limit external programming 4 Set SW1 position 3 to select the programming voltage range Down 0 5V Up 0 10V 5 Set SW1 position 4 to select the monitoring range Down 0 5V Up 0 10V...

Страница 76: ...ade only by the manufacturer or by authorized service facilities no parts replacement information is provided in the manual In case of failure unusual or erratic operation of the unit contact a Lambda...

Страница 77: ...eck if the unit is installed adjacent to heat generating equipment Check Foldback setting and load current Connect the sense wires according to User s manual instructions Turn Off the AC power and wai...

Страница 78: ...Pressluft um das Ger t von Staub zu befreien 9 4 Justagen und Kalibrierung Interne Justage oder Kalibrierung ist nicht n tig Es gibt keinen Grund die Stromversorgung zu ffnen 9 5 Bauteilewechsel und...

Страница 79: ...itet das Ger t im Konstantspannungs Modus Strombegrenzung und Spannungseinstellungen pr fen 5 2 Die Ausgangsspannung hat eine hohe Restwelligkeit Werden die Sense Anschl sse benutzt Ist der Spannungsf...

Страница 80: ...erung ausl sen so muss das Ger t zur Reparatur gegeben werden Sicherungen d rfen ausschlie lich von daf r geschultem technischen Personal ausgewechselt werden In Tabelle 9 2 sind die Sicherungswerte a...

Страница 81: ...power supplies line feed local operation local sensing lock front panel maintenance otp outline over voltage parallel operation parity ps_ok preview rack mounting rear panel remote sensing remote loc...

Страница 82: ...Nilai Industrial Estate 71800 Nilai Negeri Sembilan Malaysia Tel 60 6 799 1130 Fax 60 6 799 3277 www tdk lambda com my NORTH AMERICA TDK Lambda Americas Inc 405 Essex Rd Neptune NJ 07753 Tel 1 732 92...

Отзывы: