57
57
NOTE:
The power supply can accept values higher by 5% than
the table values, however it is not recommended to
program the power supply over the rated values.
7.7.7 Status control commands
Refer to section 7-8 for definition of the registers.
Command
#
Description
1
STT?
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
Table 7-5: OVP programming range
Table 7-6: UVL programming range
Model
Rated Output Voltage (V)
Minimum
(V)
Maximum
(V)
8
10
16
20
30
40
60
80
100
150
200
300
400
500
600
0.5
0.5
1.0
1.0
2.0
2.0.
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
10.0
12.0
19.0
24.0
36.0
44.0
66.0
88.0
Model
Rated Output Voltage (V)
Minimum
(V)
Maximum
(V)
8
10
16
20
30
40
60
80
100
150
200
300
400
500
600
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
7.60
9.50
15.2
19.0
28.5
38.0
57.0
76.0
95.0
142
190
285
380
475
570
MV<actual (measured) voltage>
PV<programmed (set) voltage>
MC<actual (measured) current>
PC<programmed (set) current>
SR<status register, 2-digit hex>
FR<fault register, 2-digit hex>
Example response: MV(45.201),PV(45),MC(4.3257),PC(10),SR(30),FR(00)
Reads Fault Conditional Register. Return 2-digit hex.
Set Fault Enable Register using 2-digit hex.
Reads Fault Enable Register. Returns 2-digit hex.
Reads Fault Event Register. Returns 2-digit hex. Clears bits of Fault Event Register.
Reads Status Conditional Register. Returns 2-digit hex.
Sets Status Enable Register using 2-digit hex.
Reads Status Enable Register. Returns 2-digit hex.
Reads Status Event register. Returns 2-digit hex. Clears bits of Status Event register.
2
3
4
5
6
7
8
9
FLT?
FENA
FENA?
FEVE?
STAT?
SENA
SENA?
SEVE?
Minimum
(A)
Model
Maximum
(A)
GEN8-600
GEN10-500
GEN16-310
GEN20-250
GEN30-170
GEN40-125
GEN60-85
GEN80-65
GEN100-50
GEN150-34
GEN200-25
GEN300-17
GEN400-13
GEN500-10
GEN600-8.5
000.00
000.00
000.00
00.00
00.00
00.00
00.000
00.000
00.000
00.000
0.000
0.000
0.000
0.000
0.000
600.00
500.00
310.00
250.00
170.00
125.00
85.000
65.000
50.000
34.000
25.000
17.000
13.000
10.000
8.500
Current programming range
Table 7-4:
110
165
220
330
440
550
660