![TDK-Lambda GENESYS 750W HALF RACK Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/tdk-lambda/genesys-750w-half-rack/genesys-750w-half-rack_technical-manual_4141272074.webp)
83-507-5002 Rev. B
66
The SRQ message is: “Inn” terminated by CR, where the nn is the power supply address. The
SRQ will be generated either in Local or Remote mode.
Refer to Tables 7-10 to 7-13 for details of the Enable and Event registers.
1. Fault Enable Register
The Fault Enable Register is set to the enable faults SRQs.
Table 7-10: Fault Enable Register
BIT
Enable
bit name
Fault symbol
Bit Set condition
Bit reset condition
0 (LSB)
Spare bit
SPARE
1
AC Fail
AC
2
Over Temperature OTP
3
Foldback
FOLD
4
Over Voltage
OVP
5
Shut Off
SO
6
Output Off
OFF
7(MSB)
Enable
ENA
User command:
“FENA nn” where
nn is hexadecimal
User command: “FENA nn”
where nn is hexadecimal (if
nn=”00”, no fault SRQs will
be generated).
2. Fault Event Register
The Fault Event will set a bit if a condition occurs and it is Enabled. The register is cleared when
FEVE?, CLS or RST commands are received.
Table 7-11: Fault Event Register
BIT
Enable
bit name
Fault symbol
Bit Set condition
Bit reset condition
0 (LSB)
Spare bit
SPARE
1
AC Fail
AC
2
Over Temperature OTP
3
Foldback
FOLD
4
Over Voltage
OVP
5
Shut Off
SO
6
Output Off
OFF
7(MSB)
Enable
ENA
Fault condition
occurs and it is
enabled.
The fault can set a
bit, but when the
fault clears the bit
remains set.
Entire Event Register is
cleared when user sends
“FEVE?” command to read
the register.
“CLS” and power-up also
clear the Fault Event Reg-
ister. (The Fault Event
Register is not cleared by
RST)
Содержание GENESYS 750W HALF RACK
Страница 2: ......
Страница 3: ......
Страница 20: ...83 507 5002 Rev B 12 2 13 GENESYS TM GENH 750W POWER SUPPLIES OUTLINE DRAWINGS...