83-507-5002 Rev. B
14
3.4 RACK MOUNTING
To install a GENH750W one unit or two units side-by-side in a standard 19” Rack in 1U (1.75”)
height, use option kit P/N: GENH/RM
The Rack Mount kit allows the units to be zero stacked for maximum system flexibility and power
density without increasing the 1U height of the units.
3.4.1 Single unit installation
To install a GENH750W power supply in a standard 19” Rack in 1U (1.75”) height, using a GENH
Rack Mount kit P/N: GENH/RM.
Fig. 3-1 Single unit installation
3.4.2 Dual unit installation
To install two GENH750W power supplies side-by-side in a standard 19” Rack in 1U (1.75”)
height, using a GENH Rack Mount kit P/N: GENH/RM.