TDK-Lambda FPS1000-12 Скачать руководство пользователя страница 4

FPS

A-50

・All specifications are subject to change without notice.

ITEMS/UNITS

MODEL

FPS-S1U

Input

Voltage Range 

(*2) V

AC85 - 265 continuous (Universal input)

Frequency 

(*2) Hz

47 - 63, Single phase

Current (100/200VAC)(max) 

A

12.0 / 6.0 for each FPS1000 unit installed

Output Maximum Power 

(*1) W

3000

Function

Remote Sensing 

(*3)

Possible.

Remote ON/OFF Control 

Separate control for each FPS1000 unit, by electrical signal or dry contact. 

On: 0 - 0.6V or short.  OFF: 2 - 15V or open.

Parallel Operation 

(*6)

Possible.

Series Operation 

(*4)

Possible. Up to 2 racks of the same voltage and current rating.

Over Temperature Alarm 
Signal 

Separate control for each FPS1000 unit, open collector signal. 

Normal: ON, max.sink current: 10mA

DC OK Signal 

Separate control for each FPS1000 unit, open collector signal. 

On when Vout>80%+/-5% max.sink current: 10mA 

AC Fail Signal 

Separate control for each FPS1000 unit, open collector signal. 

On when Vin > 85VAC, max.sink current: 10mA.

AUX-BIAS Power Supply 

11.2 - 12.5VDC. Maximum output current: 0.25A x Number of installed FPS1000 units.

Output Voltage Trimming 

Possible. Refer to instruction manual.

AC Input Connector 

FPS-S1U: IEC inlet for each power supply module.  FPS-S1U/P: None

Output Terminals 

Bus-bars. Refer to outline drawing.

Number of Power Supply Modules (*5)

Maximum 3 FPS1000 modules of the same output voltage rating.

Environment

Operating Temperature 

0 to 50: 100% load. Derate 2%/

, 50 to 60.

Storage Temperature 

-30 to 85

Operating Humidity 

RH

10 - 90, no condensation.

Storage Humidity 

RH

10 - 95, no condensation.

Vibration 

Built to meet ETS 300 019

Shock 

Built to meet ETS 300 019

Isolation

Withstand Voltage 

Input-Output: 3000Vrms, 1min. Input-Ground: 2000Vrms, 1min. Output-Ground: 500Vrms, 1min.

Isolation Resistance 

More than 100M

Ω

 at 25

 and 70% RH. Output-Ground: 500VDC 

Standards Safety Standards 

UL60950-1, EN60950-1, CSA C22.2 No.60950-1 

Mechanical

Weight (typ) 

g

3700

Size (W x H x D) 

mm

440 x 44 x 351 (Refer to outline drawing.)

  (*1) For input voltage lower than 100VAC, maximum output power is 2700W.
  (*2) For cases where conformance to various safety standards (UL, EN etc.) is required, to be described as 100-240VAC (50/60Hz).
  (*3) Remote sensing can compensate up to 1V drop on each load wire.
  (*4) Not applicable for units with I

2

C bus option.

  (*5) The output of all the FPS1000 modules are connected in parallel in the rack.
  (*6) Up to 3 racks with max.8 FPS1000 units of the same voltage and current rating.

FPS-S1U Specifications