TDK-Lambda CUT75 Скачать руководство пользователя страница 3

 

 

- 2 -

TDK-Lambda 

CUT75 

Instruction Manual

 

1

Model name identification method 

CUT 75 – 522 / 

 

                                                                         

 

                                                                                                                                                                                 

 

                                                                                                         

Option 

*1

                                            *1    Blank : Standard type   

                                                                  /A : With U type chassis and cover model 

Rated Output Voltage                                              /L : With U type chassis                                                   

                                                                                      /B : With base plate model 

Output Power type                                                    /T : With terminal model     

(actual output power refer to the specification)               

 

 

                             

Series Name 

 

 

2

Terminal Explanation 

CUT75

 

 

 

L : AC Input terminal Live line (Fuse in line.) 

 

N : AC Input terminal Neutral line 

 

 :  Terminal (Protective Earth)   

 

Mounting hole (hole diameter : 

φ

3.5mm) 

This hole is connected to Protective Earth of CN1. 

 

Mounting hole (hole diameter : 

φ

3.5mm) 

 

V.ADJ : Output voltage adjust trimmer. The output voltage rises when a trimmer is turned clockwise . 

 

CH1 
V1 : CH1 + Output pin 
G1 : CH1 – Output pin 

 

CH2

 

V2 : CH2 + Output pin 
G2 : CH2 – Output pin 

 

CH3 
G3 : CH3 + Output pin 
V3 : CH3 – Output pin 

 
 
 
 
 
 
 

Содержание CUT75

Страница 1: ...ations otherwise the product will be damaged Do not use this product in environment with a strong electromagnetic field corrosive gas or conductive substances For applications which require very high...

Страница 2: ...immunity IEC61000 4 5 Level 3 Level 4 Normal mode 2kV Common mode 4kV Conducted RF immunity IEC61000 4 6 Level 3 10V Power frequency magnetic field IEC61000 4 8 Level 4 30A m Voltage dips variations i...

Страница 3: ...refer to the specification Series Name 2 Terminal Explanation CUT75 L ACInputterminalLiveline Fuse inline N AC Input terminal Neutralline Terminal ProtectiveEarth Mountinghole holediameter 3 5mm This...

Страница 4: ...3 TDK Lambda CUT75 Instruction Manual 3 Block Diagram 4 Sequence time chart ADD...

Страница 5: ...toother components when connectingorremovingconnector Useinput outputconnector housing specifiedby thetablebelow Userecommended crimpingtool Connector is notincluded withthisproduct Refer tothefollowi...

Страница 6: ...er ambient temperature or re input condition Please select input switch and fuse carefully with the high temperature and re input the power condition The Inrush Current is typical value under cold sta...

Страница 7: ...VDC For safety operation voltage setting of DC isolation tester must be done before the test Ensure that the unit is fully discharged after the test Output Protective Earth 500VDC More than 100M AC L...

Страница 8: ...contact TDK Lambda for the technical support and instructions 3 Keep more than 5mm creepage and clearance between circuitry components of output side and FG to meet the power supply withstand voltage...

Страница 9: ...B F CONVECTION COOLING L AND A MODEL 0 20 40 60 80 100 20 10 0 10 20 30 40 50 60 70 80 Ta C LOAD A C D B F E Ta C LOADING CONDITION Mounting A C D E Mounting B Mounting F 20 40 100 100 100 45 100 100...

Страница 10: ...l pieces is 8mm from each PCB corners Refer to figure below CUT75 8 8 8 8 8 8 8 8 Condition to meet Isolation Withstand Voltage standard More than 4mm More than 4mm More than 4mm More than 4mm More th...

Страница 11: ...not be satisfied Please contact us for maintenance or exchange the product which passed over the life expectancy 10 External Fuse Rating Refer to the following fuse rating when selecting the external...

Отзывы: