- 9 -
TDK-Lambda
CUT75
Instruction Manual
7-3. Mounting Method
Insert the spacer (Max
φ
6) of height more than 8mm to lift the unit. And use all mounting holes for the unit installation. The vibration spec
is specified under this mounting condition.
▥
Mounting Holes size
CUT75: 4 HOLES
3.5mm
Height more than
8mm spacer
Allowable area by metal pieces is 8mm from each PCB corners. Refer to figure below.
CUT75
8
8
8
8
8
8
8
8
▥
Condition to meet Isolation & Withstand Voltage standard.
Mo
re th
an
4m
m
Mo
re th
an
4m
m
Mo
re
t
h
an
4m
m
More than
4mm
More than
4mm
Mor
e t
h
an
8m
m
Keep 4mm space from the surfaces and sides of PCB. Especially, 8mm space is necessary from the solder surface.
If the space is not enough, the specification of isolation and withstand will not be satisfied.
Keep enough space in the power supply surroundings and the upper area of components for convection cooling.