4-5. Over Current Protection (OCP) 

These products provide the Hiccup mode with automatic recovery. OCP function operates when the output current exceeds 105% of 
maximum DC output current of specification. The outputs will be automatically recovered when the overload condition is canceled, however 
the outputs may be latched off when shorted condition happens. Never operate the unit under over current or shorted conditions for more than 
30seconds, which may leads damage or insulation failure. OCP setting is fixed and not to be adjusted externally.   

 

4-6. Output Ripple & Noise 

The standard specification for maximum ripple value is measured according to measurement circuit specified as below. When load lines are 
longer, ripple will becomes larger. In this case, electrolytic capacitor, film capacitor, etc. might be necessary to use across the load terminal. 
The output ripple cannot be measured accurately if the probe ground lead of oscilloscope is too long. 

 

 

 

4-7. Series Operation 

For series operation, either method (A) or (B) is possible. 
 

(A)

 

                                                                                                          (B) 

   

   

 

(*1)Please select a bypass diode with maximum forward current rating more than output load current. And maximum reverse voltage must 

withstand each power supply output voltage.   

 

4-8. Parallel Operation 

For parallel operation, method (B) is possible                                   
 

Load

Output

Terminal

Output

Terminal

Load

Output

Terminal

Output

Terminal

(B)  To use as Back-up Power Supply 
      1. Adjust the output voltage of each power supply to be the same.
       2. Set power supply output voltage higher by the forward voltage 
          drop (Vf) of diode. 
           Use within the specification for output voltage and output power.

(A)  To increase the output current is not possible.       

Power Supply

Power Supply

 

Содержание CUS150M1 Series

Страница 1: ...plications which require very high reliability Nuclear related equipment medical equipment traffic control equipment etc it is necessary to provide a fail safe mechanism in the end equipment Do not in...

Страница 2: ...nation Mountinghole holediameter 3 5mm Thisholeis notconnectedto ProtectiveEarth of CN1 L ACInputterminalLiveline Fuse inline N AC Input terminal Neutralline Fuse inline Earthterminal Mounting hole ho...

Страница 3: ...50M1 4 2 Output Voltage Range Output voltage is set the rated value at shipment V ADJ trimmer VR51 can adjust the output voltage within the range Output voltage range refers to the specification To tu...

Страница 4: ...er ripple will becomes larger In this case electrolytic capacitor film capacitor etc might be necessary to use across the load terminal The output ripple cannot be measured accurately if the probe gro...

Страница 5: ...set current limit of the withstand voltage test equipment to 20mA The applied voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down When timer i...

Страница 6: ...MOUNTING D LOAD LOAD LOAD 20 40 100 100 100 50 100 100 75 60 75 70 50 65 63 55 38 70 50 40 25 5 3 Mounting Method Insert the spacer Max 7mm of height more than 8mm to lift the unit And use all mountin...

Страница 7: ...ry from the solder surface If the space is not enough the specification of isolation or withstanding voltage will not be satisfied 3 Protective Earth should be connected to the earth terminal of the e...

Страница 8: ...ncluding that the unit is at fault 1 Check if the rated input voltage is connected 2 Check if the wiring of input and output is correct 3 Check if the wire thickness is enough 4 Check if the output cu...

Отзывы: