INSTRUCTION MANUAL
CHVM1R5 Series
TDKLambda
<Page>
■ ON/OFF Control
Output voltage can be turned ON/OFF by closing/opening between the ON/OFF terminal and Vin terminal.
Between ON/OFF terminal (5) and Vin terminal (2)
(1) Output OFF when opened
(2) Output ON when shortcircuited (0 0.4V, 1mA max.)
As the ON/OFF terminal is pulled up to +Vin inside the power supply, pay attention to the voltage of elements
(photocoupler, transistor, etc.) to switch the ON/OFF terminal.
Shortcircuit when ON/OFF is not controlled.
Ensure that there is no chattering to the ON/OFF terminal which affects output voltage. Output residual voltage is
0.5% or less when output is OFF under ON/OFF control (at the rated inputoutput).
■ Over current protection
The CHVM series has a builtin over current protection circuit against overload and load shortcircuit. The circuit
reduces output voltage in case of overload or load shortcircuit and automatically returns the output to normal
when the cause is eliminated.
The overcurrent protection circuit shows a drooping characteristic. Ensure that the load to be used is at least with
the minimum resistance specified for each series.
7/11
Isolated type
-Vin
ON/OFF
(5)
(2)
Nonisolated type
-Vin
ON/OFF
(5)
(2)
100
80
60
40
20
0
0
Output Current (lo) 100
%
100% output
50% output
O
u
tp
u
t
vo
lta
g
e
s
e
tti
ng
v
a
lu
e
(
%
)
CHVM series
over current protection circuit
characteristic