background image

INSTRUCTION MANUAL

CHVM1R5 Series

TDK­Lambda

<Page>

■ Description of Vref terminal (reference voltage output)

This terminal is used for controlling output voltage with a variable resistor. Vref outputs a reference voltage of 
6V. A 5KΩ external resistor is used in this case.
Since resistance value (tolerance) of an external resistor affects the Vref terminal voltage preset value and 
determines output voltage, ensure that the resistor has high accuracy of 5KΩ±5%. The type of the variable resistor 
(5KΩ) does not matter, but those of a good temperature coefficient are recommended.

■ Temperature derating

■ Protection against reverse connection

Reverse connection of input voltage may result in the breakage of a converter. If there is any possibility for a 
reverse connection, add a diode and a fuse to the input circuit as shown below.

■ Recommended soldering conditions

Observe the following conditions for soldering each part.
(1) Soldering iron

340 ­ 360°C

5 seconds

(2) Dip solder bath

230 ­ 260°C

10 seconds

10/11

Vout (com)

Vcont

Vref

Vref voltage: 6±0.3V

3

4

Reference voltage 

generating circuit

External variable resistor (5.0K

Ω

)

6

CHVM series

100 

80 

60 

40 

20 

0

­20    ­10      0    +10   +20   +30   +40   +50

O

ut

pu

t d

e

ra

tin

ra

te

 (

%

)

Ambient temperature (°C)

Can be activated in this area but without 
performance warranty.

12V

+

F1

+

Vin

-

Vin

CHVM

D1

Содержание CHVM1R5 Series

Страница 1: ...the cover as you might get an electric shock or might damage the product We will not be held responsible after the product has been modified changed or dis assembled Do not use this product under unu...

Страница 2: ...otective device inside the system providing redundant circuit to ensure no instability when single device failure occurs When used in environments with strong electromagnetic field there is possibilit...

Страница 3: ...midity the following conditions shall be used as a guideline Temperature range 5 30 Humidity range 40 60 RH Please keep away from the places where temperature and humidity can change drastically It ca...

Страница 4: ...for improvement etc without prior notice 4 11 Line regulation Load regulation Temperature regulation Over current protection Output voltage setting accuracy Operating temp range Storage temp range Op...

Страница 5: ...SW1 Open OFF Short ON C1 5 7 Output voltage control 0V to 6V applied C1 47 F OPEN Vin Vin Vout or Vout Com Vref Vcont ON OFF CASE F1 12V Vin Vin Vout or Vout Com Vcont Vref Load 1 2 7 6 3 4 Control I...

Страница 6: ...wer supply and converter an input line is thin a filter is inserted on the input side etc When fitting a capacitor try to add on the converter terminal side so as to reduce lead inductance 6 11 Pin No...

Страница 7: ...ltage Output residual voltage is 0 5 or less when output is OFF under ON OFF control at the rated input output Over current protection The CHVM series has a built in over current protection circuit ag...

Страница 8: ...ntion to creepage distance because of the high voltage of this converter 2 When mounting onto a double sided board make the round on the parts surface of the high voltage output terminal as small as p...

Страница 9: ...hat when the resistance of the variable resistor is 5 0K 6 0V is applied to the Vcont terminal to obtain 100 output voltage Since the tolerance of the resistance value largely affects the maximum outp...

Страница 10: ...icient are recommended Temperature derating Protection against reverse connection Reverse connection of input voltage may result in the breakage of a converter If there is any possibility for a revers...

Страница 11: ...age and shall be attached to the terminal end Try to make the lead wires of the capacitor the shortest possible in this case as well In addition with a load requiring a certain response speed pay atte...

Отзывы: