CONTROLS, INDICATORS, CONNECTORS
83489011 Rev A
5-2
REF
DESCRIPTION
NOTE
SECTION
1
HV ON Push Button
Turns ON HV output
5.2
2
Output Status
Output Status LEDs
5.3
3
Local Voltage Set
10 turn pot for setting output voltage in local mode
5.4
4
Voltage Bar Graph
Analog bar graph showing output voltage (%)
5.5
5
Voltage Display
Digital display of output or set voltage
5.6
6
Current Display
Digital display of average output current
5.7
7
HV OFF Push Button
Turns OFF HV output and resets latching faults
5.8
8
Local/Remote
Keyswitch
Switches control between remote, local, and off modes
5.9
9
Status LEDs
Detailed status LED displaying showing operating condi-
tion and any faults
5.10
10
View set push button
Push to view the output voltage set point in local mode
5.11
11
Current Bar Graph
Analog bar graph showing output current (%)
5.12
12
Power switch
Turns on/off power to auxiliary circuits
5.13
Table 5-1 Front Panel Controls and Indicators (L Model)
The front panel controls/indicators are described in detail in the following sections.
5.2
HV ON (Ref 1)
DO NOT DEPRESS THE HV ON PUSH-BUTTON UNLESS A
SUITABLE CAPACITIVE LOAD IS CONNECTED TO THE
POWER SUPPLY'S OUTPUT CABLE, AND THE LOAD IS
CORRECTLY GROUNDED
The HV ON push button turns ON the high voltage output when depressed only after all
interlocks are closed, self checks are completed and the unit is switched to the LOCAL
mode. HIGH VOLTAGE will be generated immediately when the HV ON is depressed
and the HV ON LED will illuminate and remain illuminated while the HV is ON. The sup-
ply will charge the load to the voltage determined by the HV LEVEL ADJUST 10 turn
pot. It is good practice to turn the LOCAL VOLTAGE CONTROL pot fully counterclock-
wise (to zero) before pushing the HV ON button when first using this power supply. Lat-
er on during system usage, the LOCAL VOLTAGE CONTROL may be left set at the de-
sired level.
If a fault is present when the HV ON push-button is depressed, the SUMMARY FAULT
LED will illuminate.
5.3
OUTPUT STATUS LEDs (Ref 2)
There are 6 output status LEDs on the front panel, indicating the state of the HV Output
circuit and some of the fault detection circuits in the control system.
Содержание 203
Страница 2: ......
Страница 12: ...GENERAL INFORMATION 83489011 Rev A 1 6 NOTES...
Страница 16: ...SPECIFICATIONS 83489011 Rev A 2 10 NOTES...
Страница 24: ...INSTALLATION 83489011 Rev A 4 18 NOTES...
Страница 46: ...OPERATING INSTRUCTIONS 83489011 Rev A 7 22 NOTES...
Страница 48: ......
Страница 49: ...010481200rev3 sch 1 Tue Nov 13 15 40 12 2012...
Страница 50: ...010481200rev3 sch 2 Tue Nov 13 15 40 12 2012...
Страница 51: ...010481300rev7 sch 1 Thu Jun 21 13 40 36 2012...
Страница 52: ...010481300rev7 sch 2 Thu Jun 21 13 40 36 2012...
Страница 53: ...010481300rev7 sch 3 Thu Jun 21 13 40 36 2012...
Страница 54: ...010481300rev7 sch 4 Thu Jun 21 13 40 36 2012...
Страница 55: ...010481300rev7 sch 5 Thu Jun 21 13 40 36 2012...
Страница 56: ...010481300rev7 sch 6 Thu Jun 21 13 40 36 2012...
Страница 57: ...010481300rev7 sch 7 Thu Jun 21 13 40 36 2012...
Страница 58: ...010481300rev7 sch 8 Thu Jun 21 13 40 37 2012...
Страница 59: ...010481300rev7 sch 9 Thu Jun 21 13 40 37 2012...
Страница 60: ...010481300rev7 sch 10 Thu Jun 21 13 40 37 2012...