WCL488 Series Water Cooled Electronic Loads
Operation & Programming Manual
TDI-Dynaload Division
Page 118
402828, Rev. B1
Symptom
Possible Cause
Explanation/Corrective Action
All slave units not powered up
(AC).
Apply AC power to all slave units.
Slave bit identifier switch not
properly set.
Check all switch positions (watch
for more than one unit set at the
same number).
System does not
recognize total
number of slave units
in system.
Bad master/slave cable.
Inspect cable for cuts and shorts.
Replace if necessary.
Slave bit identifier switch not
properly set.
Check all switch positions (watch
for more than one unit set at the
same number).
Bad master/slave cable.
Inspect cable for cuts and shorts.
Replace if necessary.
Gross errors in current
level.
Bad slave unit.
Replace faulty slave unit.