background image

DKC1500 SERIES SLIDING GATE OPERATOR USER

’S MANUAL 

40mm

15

25mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig.4 

Conduit 

In order to protect the wires, conduit must be preset into the concrete when it is poured. Wires 

within the conduit shall be located or protected so that no damage can result from contact with 

any rough or sharp part. If you have installed an external button switch, we advise  you to use 

two  conduits:  one  for  main  power  wire,  another  one  for  control  wire.  Always  separate  power 

wires from control wires. 

Concrete pad 

The base unit of the gate operator requires a concrete pad in order to maintain proper stability.   

The concrete pad should be approximately 400mm x 250mm x 200mm deep in order to provide 

for adequate operation.     

Anchors   

You can use the anchor bolts, anchors, washers, and nuts. These anchors must be set into the 

concrete when it is poured, or you can use wedge anchors. 

 

 

 

 

 

 

 

 

 

 

                                                                       

 

 

Fig.5 

Содержание DKC1500 Series

Страница 1: ...CED TECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Total Door...

Страница 2: ...UAL 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Technical parameters 3 4 Working principle and main structure 4 5 Manual operation 4 6 Packing list 4 7 Installation and adjustment 5...

Страница 3: ...mity to moving parts where hands or fingers could be pinched It is necessary to install the located blocks on two ends of guide Do not allow control devices to be placed so that a person can access th...

Страница 4: ...manual release key to open or close gate manually use the release key as follow Fit the release key in the lock Turn the key about 4 6 circles anticlockwise Open or close the gate manually Note If the...

Страница 5: ...2 Anchor bolts for mounting operator 4 3 Magnet 2 4 High low bracket 1 5 Block 1 optional 6 Release key 2 7 Remote control 2 7 Installation and adjustment Fig 3 The DKC1500 series rack driven gate ope...

Страница 6: ...button switch we advise you to use two conduits one for main power wire another one for control wire Always separate power wires from control wires Concrete pad The base unit of the gate operator req...

Страница 7: ...alled to ensure it meshes correctly with the gear The space between rack and gear is about 1 2mm Fig 6 Magnets for limit switch Install the magnet as shown in Fig 7 and Fig 8 below The magnet and limi...

Страница 8: ...e rails must be installed horizontally Install the plastic block as shown in Fig 7 and a Fig 8 The spring limit switch and blocks are used to control the position of the gate Release the gear clutch w...

Страница 9: ...lectrical Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again Refer to Fig 11 control board sche...

Страница 10: ...Indicator light learn LED2 11 Receiver 12 MCU stm8s103 13 Limit switch N C OP open GND com CL close Snip short wire S2 Limit switch N O OP GND CL Wiring Open Com Close N C for N C limit switch Open C...

Страница 11: ...erase all existing remote controls press and hold LEARN button about 8 seconds till the LED2 turns on and turns off This indicates that all the remote controls have been erased completely Warning For...

Страница 12: ...button 4 of remote control or pedestrian button switch the gate will open about 1 2 meters for people pass through after passing through the gate the gate will close automatically Adjustment of openi...

Страница 13: ...than 15 minutes If it is runs continually for an extended period of time a thermal protector will stop it because of the high temperature 10 Maintenance Ensure the operator is well earthed and correct...