1. Important safety information 

Carefully  read  and  follow  all  safety  precaution  and  warnings  before  attempting  to  install  and  use 

DC660-3(L, M, R) boom gate. Incorrect installation can lead to severe injury. 

 

The automatic boom gate should be installed by a qualified technician; otherwise, serious personal 

injury or property damage may occur. 

 

Children should not be allowed to play near or operate automatic boom gate. 

 

Before any job on the boom gate, cut out electrical power. 

 

Do not in any way modify the components of the automatic boom gate, otherwise serious personal 

injury  or  property  damage  may  occur.  We  do  not  accept  responsibility  for  damage  or  injury 

resulting from installing this boom gate. 

 

Notify the users that the boom gate is never to be operated unless it is in full view. 

 

Always keep people and objects away from the boom gate when it is operated.   

 

Keep  remote  controls  away  from  children,  to  prevent  the  boom  gate  from  being  activated 

involuntarily. 

 

The distance between the end of the bar and the nearest objects should exceed 0.5m. 

 

Any changing of the bar by customer is not allowed. If you have any special requirements about 

the bar, please kindly contact a dealer. 

 

Under no condition should boom gate be used with bar or spring not attached. 

 

For your safety, withdraw the crank before switching the power back on. 

 

For service, call an experienced technician. 

 

Our company reserves the right to change the design and specification without prior notification. 

 

2. Introduction 

Please read the instructions carefully before proceeding. The automatic boom gate intended for use in 

parking area, commercial premises or apartment block access. 

 

Compact design, attractive appearance, safe and reliable performance. 

 

Self-locking at any position. 

 

A unique internal spring counterbalance mechanism aids the action of the boom gate. 

 

To  ensure  safety,  the  boom  gate  will  reverse  if  it  comes  in  contact  with  people  or  vehicle  when 

closing, and will stop if jammed when opening. 

 

Manual operation in case of power failure. 

 

Terminals available to photocell, loop detector and alarm lamp. 

 

3. Main technical parameters 

Type   

DC535Y/DCZ535Y 

DC655Y/DCZ655Y 

Opening time

 

3.5 seconds

 

5.5 seconds 

Bar length

 

3m~5m (standard)

 

5m~6m (standard) 

Power supply

 

Single-phase AC240V 50Hz 

Motor speed

 

1400r/min 

Motor output power

 

180W 

Duty cycle

 

40% 

Noise

 

≤62dB 

Measurement 

360mm (L) x 230mm (W) x 1050mm (H) 

Environmental temperature 

-20

º

C~+50

º

Содержание DC535Y

Страница 1: ...PERIENCED TECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Tota...

Страница 2: ...C655Y DCZ655Y BOOM GATE USER S MANUAL 2 OUTLINE 1 Important safety information 3 2 Introduction 3 3 Main technical parameters 3 4 Installation 4 5 Electrical 9 6 Maintenance 13 7 Troubleshooting 13 8...

Страница 3: ...customer is not allowed If you have any special requirements about the bar please kindly contact a dealer Under no condition should boom gate be used with bar or spring not attached For your safety w...

Страница 4: ...4 Installation Necessary Tools The following tools may be necessary to install the automatic boom gate You will need standard screwdrivers an electric drill and spanners The entire configuration and...

Страница 5: ...another one for control wires Always separate power wires from control wires Wire The power wire size should be more than 1 5mm The control wire size should be more than 0 5mm 2 Fig 3 Expansion bolt s...

Страница 6: ...cle and lock it with the four M10 16 socket head screws Mount the bar cover using the three M4 5 screws Manual operation see Fig 6 In case of power failure use crank to open or close boom gate manuall...

Страница 7: ...open limit cam until the open limit switch light illuminated then tighten the screws Loose the M4 screw of close limit cam turn the close limit cam until the close limit switch illuminated then tight...

Страница 8: ...suitable for bar length from 4 5m 5m If you need to change it to the third 3 5m 4 5m or the fourth 3m 3 5m hole proceed as follows When the balancing spring is loose the bar is in open position undo t...

Страница 9: ...n erased completely The remote control works in a single channel mode With each press of the remote control button the bar will open stop close or stop cycle DIP switch SW Position DIP switch Function...

Страница 10: ...sistance may be increased or decreased by rotating clockwise or counterclockwise If the boom gate operates freely and can auto reverse in the event of an obstruction during closing and stop in the eve...

Страница 11: ...DC535Y DCZ535Y DC655Y DCZ655Y BOOM GATE USER S MANUAL 11 Fig 10 control board scheme...

Страница 12: ...r supply 12V DC 12V COM GND CO DET Loop detector normally open contact I R Infrared normally close contact COM GND 12V Out COM I R COM 12V Terminal X8 No 10 Terminal X8 No 10 I R COM Out COM AC24V AC2...

Страница 13: ...he two M10 socket head screws in the driven lever Check if all screws and nuts have been tightened firmly except oil screw as shown in Fig 11 Check if all wires are firmly connected to their respectiv...

Страница 14: ...t If any parts appear to be missing contact a dealer No Item Quantity 1 Assembled cubicle 1 2 Bar locking bracket 1 3 Bar cover 1 4 Cover 1 5 Crank 1 6 Transmitter 2 7 Button switch optional accessory...

Отзывы: