DC535Y/DCZ535Y, DC655Y/DCZ655Y BOOM GATE USER
’S MANUAL
3
1. Important safety information
Carefully read and follow all safety precaution and warnings before attempting to install and use
DC660-3(L, M, R) boom gate. Incorrect installation can lead to severe injury.
⚫
The automatic boom gate should be installed by a qualified technician; otherwise, serious personal
injury or property damage may occur.
⚫
Children should not be allowed to play near or operate automatic boom gate.
⚫
Before any job on the boom gate, cut out electrical power.
⚫
Do not in any way modify the components of the automatic boom gate, otherwise serious personal
injury or property damage may occur. We do not accept responsibility for damage or injury
resulting from installing this boom gate.
⚫
Notify the users that the boom gate is never to be operated unless it is in full view.
⚫
Always keep people and objects away from the boom gate when it is operated.
⚫
Keep remote controls away from children, to prevent the boom gate from being activated
involuntarily.
⚫
The distance between the end of the bar and the nearest objects should exceed 0.5m.
⚫
Any changing of the bar by customer is not allowed. If you have any special requirements about
the bar, please kindly contact a dealer.
⚫
Under no condition should boom gate be used with bar or spring not attached.
⚫
For your safety, withdraw the crank before switching the power back on.
⚫
For service, call an experienced technician.
⚫
Our company reserves the right to change the design and specification without prior notification.
2. Introduction
Please read the instructions carefully before proceeding. The automatic boom gate intended for use in
parking area, commercial premises or apartment block access.
⚫
Compact design, attractive appearance, safe and reliable performance.
⚫
Self-locking at any position.
⚫
A unique internal spring counterbalance mechanism aids the action of the boom gate.
⚫
To ensure safety, the boom gate will reverse if it comes in contact with people or vehicle when
closing, and will stop if jammed when opening.
⚫
Manual operation in case of power failure.
⚫
Terminals available to photocell, loop detector and alarm lamp.
3. Main technical parameters
Type
DC535Y/DCZ535Y
DC655Y/DCZ655Y
Opening time
3.5 seconds
5.5 seconds
Bar length
3m~5m (standard)
5m~6m (standard)
Power supply
Single-phase AC240V 50Hz
Motor speed
1400r/min
Motor output power
180W
Duty cycle
40%
Noise
≤62dB
Measurement
360mm (L) x 230mm (W) x 1050mm (H)
Environmental temperature
-20
º
C~+50
º
C