background image

For self-testing

TD-4277B

 

TaiDoc Technology Corporation

 

Bi.7F,No.127,Wugong 2nd Rd.,

 

Wugu Dist., 24888 New Taipei City, Taiwan

 

MedNet EC-REP GmbH

 

BorkstraBe 10, 48163 Münster, Germany 

Import Europa: HT Medical BV

 

Distributor: GD Medical Pharma BV

Hastelweg 224, 5652 CL Eindhoven

[email protected]

The Bluetooth® word mark and logos are registered trademarks 

owned by Bluetooth SIG, Inc. and any use of such marks by HT Medical BV 

is under license.Other trademarks and trade names are those of their 

respective owners.

Содержание GLUCO TD-4277B

Страница 1: ...BLOOD SUGAR CONTROL SYSTEM User Manual TD 4277B version 2 0 2016 03 HT102015B 01G 311 4277200 002...

Страница 2: ...hould you have any further queries after reading this manual please contact your local customer support or your distributor Use This system is intended for exterior use in vitro diagnostic use in a no...

Страница 3: ...at could mean incorrect results 9 Do NOT use the meter near sources of strong electromagnetic currents as the accuracy of the measurement could be affected 10 Proper maintenance is essential to the op...

Страница 4: ...ue to receive results that are lower or higher than normal then contact your GP and follow their advice Only use fresh whole blood samples for testing your blood sugar levels Using any other substance...

Страница 5: ...ld be incorrect if the contact point is not fully inserted into the test slot NOTE The TD GLUCO Bluetooth meter may only be used with TD GLUCO TD 4360 test strips Using other test strips with this met...

Страница 6: ...o switch between the General AC PC and QC modes Before using your meter for the first time or whenever you replace the battery check and adjust the following settings Launching the setup mode a Start...

Страница 7: ...wipe it off Squeeze another droplet onto the point of the bottle s cap Hold the meter so that the absorbent opening of the test strip comes into contact with the drop and absorbs the control solution...

Страница 8: ...full when enough blood is applied Do NOT take your finger away before the device beeps WARNING In order to limit the chance of an infection Never share a lancet or lancing device with others Always us...

Страница 9: ...ance with the local regulations 16 17 The meter stores the 1 000 most recent blood sugar test results together with their dates and times In order to access these records start with the device turned...

Страница 10: ...unique four digit letter combination of the Bluetooth MAC associated with your meter 4 Add your meter press and press Yes to save the settings 5 Once the devices are linked the data in your meter wil...

Страница 11: ...nlight and heat Reseal the tube immediately after removing a test strip Ensure that your hands are clean and dry before touching a test strip Battery Your meter comes with two 1 5 VAAA alkaline batter...

Страница 12: ...order to guarantee a pure sample and accurate result Keep the control solution properly sealed at a temperature between 2 C and 30 C 35 6 F and 86 F DO NOT freeze If you perform the recommended actio...

Страница 13: ...upside down or not full inserted Meter or test strips are defective Insufficient blood sample Defective test strip Sample has been applied after the device automatically switched off 5 minutes after...

Страница 14: ...Temperature warning Operating conditions 10 C to 40 C 50 F to 104 F under 85 relative humidity non condensing Meter storage transport conditions 20 C to 60 C 4 F to 140 F under 95 relative humidity T...