Change Settings
Once the password is entered you will see the first setting (P01) appear on the screen. Press “mode”
again to view the setting for P01. If a setting change is needed use the scroll arrows to change as
needed.
Set all of the AC-Tech parameters from the below list.
AC - Tech Parameters
01
Line Voltage
High=01,
Low=02
Low voltage is for 220V and below.
04
Stop Method
Ramp=03
05
Standard Speed
Preset #1=02
06
TB-14 Output
Run=02
09
TB-31 Output
None=01, Dynamic Braking=04
(if break installed set to 04)
10
TB13A Function
None=01, DB Fault=09
(if break installed set to 09)
19
Acceleration Time
Set to “
12
” seconds
20
Deceleration Time
Set to “
12
” seconds with dynamic break otherwise “60” seconds
25
Current Limit
100
%
26
Motor Overload
72
%
31-37
Preset Speeds
60
Hz