background image

07/2015 

15 

 

TCS TürControlSysteme AG

 

Subject to technical changes. 

E-

Mail: [email protected]   •  www.tcsag.de

 

PI_ISW3130-uk                                2 A 

 

Initiate 

power supply and control unit 

 

 

 

 

RUN/PROG push 
Button: press short 

LED blinks 

 

 
 
 

 

 

  

 
 
 
 

programming mode of the system is switched on  

 

Delete a button

 a)

 

 

 

 

 
 
 

   

 

 
 

 
 
 

 

 

 

press until the delete-tone-melody sounds 

1)

 

 

release 

 

Programming via voice connection  

 

or

 

 
 
 

 

 
 

 

 
 
 

 

 

 

 

 

 

establish voice communication  
to the front-station 

2)

 

 

shortly press  
the button 

 

... a ring tone sounds at the front-door 
and indoor station

1)

 

 

End 

power supply and control unit 

 

 

 

 

RUN/PROG-push 
button: shortly press 

           LED is ON 

 
 
 

 

 

 

 
 
 

programming mode of the system is switched off *

)

 

 

a) Not necessary, if the bell buttons have not been programmed, comp. product information of the front-door station. 
1) If there sounds a Progsperr tone instead, the front-door station is equipped with a programming lock.  

The programming lock can be deactivated only with the Service Device TCSK-01 or the configuration software 
configo™. 

2) New developed front-door stations (as of 2009) respond to that with a positive acknowledgement, if the serial number 

of the indoor station was received (see product information of the front-door station). 

*)

 

for device specific indication modes of t he front-door station see product information of the front-door station 

 

Cleaning 

 

!

 

Avoid water from entering the device! 
Do not use any abrasive detergents! 

 

Clean the device with a dry or slightly moist cloth. 
Remove stronger stains with a mild plastic cleaner. 

Содержание ISW3130

Страница 1: ...TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISW3130 uk 2 A Product information Comfort indoor station for hands free talking ISW3130...

Страница 2: ...the upper cover 7 Open the device 7 Installation of extended functions 8 Connect the lines 8 Connection lines 8 Wiring example 9 Connection diagram 2 wire technique 9 Connection diagram 3 wire techniq...

Страница 3: ...separators between heavy and low current lines in shared cable ducts use of standard telecommunication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sectio...

Страница 4: ...OFF is activated flashes ring tone stopper is deactivated door release automatic or call diversion is activated flashes OFF ring tone stopper is activated door re lease automatic or call diversion is...

Страница 5: ...rs like shown in price list dimensions in mm H 180 x W 100 x D 23 weight 185 g acceptable ambient temperature 5 40 C degree of protection IP30 input current stand by 2 wire operation I a 1 mA 3 wire o...

Страница 6: ...oftware configo flat door floor door and internal call a parallel call can be activated with the Service Device TCSK 01 or configo audio privacy function and automatic call cut OFF after 2 min lower c...

Страница 7: ...from the button to the top floor push button at a E Wiring example see page 9 Snap on the upper cover Set on the upper cover at both adjustment increments of the lower cover 1 Snap on the upper cover...

Страница 8: ...the indoor station with adhesive pads see also product information of each extended function Connecting the lines is implemented in analog to the ISW3030 see product information TRE1 EB 1 Connect the...

Страница 9: ...2015 9 TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISW3130 uk 2 A Wiring example Connection diagram 2 wire technique Connection diagram 3 wire techniq...

Страница 10: ...check if it is connected to the a wire of the power supply and control unit Settings Preset times conversation time 2 min flashing period of the green LED if the voice channel is busy after establishi...

Страница 11: ...control key until the required ring tone sounds The ring tone selected last is stored 3 Short press the call OFF button Or If no button is pressed for around 8 sec the device end the ring tone select...

Страница 12: ...x unlimited communication time x reset to factory settings x If the floor door release function in the EEPROM has been activated and the door release automatic function via function key is switched on...

Страница 13: ...other and put it one sided on mass b wire in the power supply optional strand or star formed wiring Table loop resistance cable length in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 7...

Страница 14: ...r not supplied connect the a wire or check power supply device is in stand by mode again button stucks press longer than 15 sec remove button at the device or loosen floor push but ton device is in st...

Страница 15: ...Not necessary if the bell buttons have not been programmed comp product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a prog...

Страница 16: ...ecting point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electri...