Preset factory settings
The device is equipped with an EEPROM. Here the following device settings are stored:
programming lock
OFF (= 0)
can be programmed with IR remote control
ON (= 1)
operation with IR remote control
ON (= 1)
master code
serial number of the device
parallel serial numbers SNo 1 and SNo 2
0
sound profile
floor call
internal call
door call 1, door call 2
sub-door call 1, 2, 3, 4
1 (ISH3030)
2
6
10, 10
7, 8, 9, 11
optical call display, period
2 (blinks), 30 s
volume ring tone
6
volume announcement
7
audio AS-threshold
0
alarm group
63
Load factory setting via push-button
!
Attention! When loading the factory settings, the master code and all settings set by
the user will be lost.
To press the push-button factory setting, use a suitable tool e.g. small screwdriver, wire
or the like.
LED, red OFF or ON
LED, red blinks
LED, red blinks fast
LED, red is ON
Press push-button
load factory settings
and keep pressed
…
…
…, until LED, red
blinks fast, then re-
lease button
factory setting is
loaded
Programming with IR remote control
Important notes
The programming must always be initiated and terminated resp. is terminated by the
device.
When the input is correct, a positive acknowledgement tone (
) sounds.
If the entry of an instruction sequence (
… … ) is interrupted for 8 seconds,
the whole instruction sequence is rejected, a negative acknowledgement tone (
)
sounds.
If the entered instruction sequence does not correspond to the given syntax, or if too