Set optical call indication  

For 8 different incoming calls, (door calls from 2 different front-door stations, floor call, in-
ternal call, sub-door calls 1to 4) different flashing sequences of the blue lighting bar as well 
as their respective duration after the incoming call can be set.   
 

Initiate 
programming  

 

 

If not yet done  

 
 

 

enter 
 

 

 

 

… 



… 

  
 
 
 
  
 
 
  

 

 

 

* 4x # flashing sequence # duration # 
 
x  = 1  floor call 

 

(WE* = 1 # 30) 

  = 2  internal call 

 

(WE* = 1 # 30) 

  = 3  door call 1 (AS less or equal audio AS-

threshold)        

 

(WE* = 2 # 30) 

  = 4  door call 2 (AS larger than audio AS-

threshold)           

 

(WE* = 2 # 30) 

  = 5  sub-door call 1   

(WE* = 2 # 30) 

  = 6  sub-door call 2   

(WE* = 2 # 30) 

  = 7  sub-door call 3   

(WE* = 2 # 30) 

  = 8  sub-door call 4   

(WE* = 2 # 30) 

  = 9  GFA-call 

 

(WE* = 1 # 30) 

 
flashing sequence 
  = 0  OFF 
  = 1  blinks fast 
  = 2  blinks 
  = 3  flashes 1:7 (0.5 s ON / 3.5 s OFF) 
  = 4  flashes 7:1 (3.5 s ON / 0.5 s OFF) 
 
duration 
  = 1 to 120 s   
  = 0 when door call: =door standby time, 
        when internal call and floor call: 30 s 
 

 

 
 

correct values has 
been entered  
 
 

 

 
 

  A positive acknowledgement tone sounds, 

 
the red LED acknowledges with selected 
flashing sequence (e.g.

 

flashing

 

1:7),

 

dura-

tion 5 s. 
then the red LED is ON for 3 s. 
 

  Then the red LED blinks. 

 

The selected optical call indication is stored.  

 

   

 

 

   

 

select further optical 
call indications  

 

Repeat the process. 

 

incorrect value has 
been entered 

  

 

A negative acknowledgement tone sounds 
when pressing the #-key. 
 
The red LED blinks fast for 3 s,  
 
then blinks again. 

 

   

 

 

   

 

 

* WE = factory setting 

 
 

Содержание FIL1101-0140

Страница 1: ...TCS T rControlSysteme AG TCS Hotline Germany Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de FIL1101 UK 1A mi Product information Signal Unit FIL1101 0140...

Страница 2: ...figurations 8 Preset factory settings 9 Programming with IR remote control 9 Important notes 9 ATTENTION Change master code 10 Initiate programming 10 Parallel allocation to serial numbers 1 and 2 11...

Страница 3: ...neral safety regulations for telecommunication systems according to VDE 0800 must be observed Inter alia separated conduit of heavy and low current lines minimum distance of 10 cm in case of a common...

Страница 4: ...t housing plastics white dimensions in mm W 98 x H 98 x D 12 weight 100 g acceptable ambient temperature 5 C 40 C input current standby 2 wire operation I a 1 5 mA 3 wire operation I a 0 2 mA I P 1 3...

Страница 5: ...L1101 Short description 39 different ring tones 3 different sound profiles ISH1030 ISH3030 Skyline can be adjusted via IR remote control optical call display via blue lighting bar call distinction for...

Страница 6: ...er to place the lines without any prob lems and to prevent clamping the lines when snapping on the up per cover Loosen the screws of the con nection terminal and connect the lines according to the lab...

Страница 7: ...r to both adjustment increments at the lower cover 1 2 Snap on the upper cover 2 Open the device 3 There is s a release opening at the under side of the device Insert a screw driver with ca 7 mm width...

Страница 8: ...r internal call x x select ring tone for door call 1 AS less or equal audio AS threshold x x select ring tone for door call 2 AS less or equal audio AS threshold x x select ring tone for sub door call...

Страница 9: ...ad factory setting via push button Attention When loading the factory settings the master code and all settings set by the user will be lost To press the push button factory setting use a suitable too...

Страница 10: ...mming Authorisation via IR remote control Keystroke is acknowledged by the device with a brief button acknowledgement tone Note If the ring tone output is switched off the red LED goes OFF with the fi...

Страница 11: ...l numbers 1 and 2 Initiate programming If not yet done Enter 11 SNo 1 12 SNo 2 SNo 1 and 2 0 to 999999 WE 0 If SNo 0 is entered parallel allocation is deactivated SNo serial number of the indoor stati...

Страница 12: ...d WE 10 4 door call 2 AS less or equal audio AS threshold WE 10 5 sub door call 1 WE 7 6 sub door call 2 WE 8 7 sub door call 3 WE 9 8 sub door call 4 WE 11 ring tone 0 to 12 each in every sound profi...

Страница 13: ...china 3 alpha tone 4 melody 2 doorbell 4 alpha tone 5 alpha tone 1 fanfare 5 alpha tone 6 horch horch 6 gong tone single bigben bell 7 gong tone double 1 elise djingle 8 gong tone double 2 melody 3 t...

Страница 14: ...dio AS threshold WE 2 30 5 sub door call 1 WE 2 30 6 sub door call 2 WE 2 30 7 sub door call 3 WE 2 30 8 sub door call 4 WE 2 30 9 GFA call WE 1 30 flashing sequence 0 OFF 1 blinks fast 2 blinks 3 fla...

Страница 15: ...is stored incorrect value has been entered A negative acknowledgement tone sounds when pressing the key The the red LED blinks fast for 3 s then blinks again Set audio AS threshold for call distinctio...

Страница 16: ...stored incorrect value has been entered A negative acknowledgement tone sounds when pressing the key The the red LED blinks fast for 3 s then blinks again WE factory setting Change master code Initia...

Страница 17: ...d A positive acknowledgement tone sounds the red LED is ON for 3 s Then the red LED blinks incorrect entry un known master code A negative acknowledgement tone sounds when pressing the key The red LED...

Страница 18: ...t tone red LED is ON 3 switch ON ring tone output the last ring tone sounds red LED is OFF 4 decrease volume The ring tone selected last sounds with the decreased volume the new value is stored 5 incr...

Страница 19: ...battery 7 Attach the cover Attention Because the risk of explosion the button cells must not be recharged Do not dispose batteries as ordinary domestic waste Batteries must be delivered to a collecti...

Страница 20: ...tion point for electronic waste Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electrici...

Отзывы: