2800 LAURA LANE • MIDDLETON, WI 53562 • (800) 288-9383 • FAX (608) 836-9044 • www.tcsbasys.com
7
MON
72F
12:00 AM
SET DATE:
11-19-01
3.
1.
clock
setup
ENTER ACCESS
SET TIME & DAY:
MON
12:00 AM
2.
000
CODE
fan
Occupied
Heating
Cooling
Fan
Service
Program/
COOLER
WARMER
Data
switch
service
status
system
switch
program
setup
clock
setup
override
override
override
clock
setup
clock
setup
clock
setup
11-19-01
Main Monitoring Screen.
Press the
clock setup button to access the follow-
ing screens. (Date not shown on the
SZ1024.)
Access Code Entry Screen.
May
appear if access code is required for
setting clock and schedules. Use 248 as
the default. If the wrong code is entered,
it will revert to the previous screen.
Time and Day Screen.
Set the hour,
minutes, AM or PM, and day of the
week.
Date Screen.
Set the month, date, and
year. (Not available on SZ1024.)
Schedule Announcement Screen.
Announces the next screen.
Setting Clock & Schedule
The SZ1024 and SZ1033 clock and schedule may be
set through the keypad and display, or with a PC. For
more information on programming through the PC, con-
sult your TCS software manual.
SETTING CLOCK & SCHEDULE THROUGH THE
KEYPAD
To access the clock and schedule screens, press the
clock setup button. To make changes, use the warmer
and cooler keys. For screens that have more than one
field to set, use the override key to move to the next
field. Access may be locked out with dipswitches, or an
access code may be required.
MODE CONVERSION TABLE SZ1024/33 & SZ1022/31
• Compressor 1 Becomes Cool 1
• Compressor 2 Becomes Cool 2
• Aux. Heat 1 Becomes Heat 1
• Aux. Heat 2 Becomes Heat 2
• “Emergency Heat” Mode does not exist
• “Aux. Heat 1” Must be enabled (Step 24) for heat to work in
conventional mode
• Power up start up screen still displays “SZ1024”
or “SZ1033”
• Everything else, not mentioned here, remain same as if it
is SZ1024/SZ1033
• Reversing valve output has no meaning
R
program
setup
REQUIRE CODE FOR
PROGRAMMING? NO
50.
program
setup
REQUIRE CODE FOR
CLOCK/SCHED? YES
51.
program
setup
SET ACCESS
CODE: 248
52.
MON.
11-19-01
12:00 AM 72F
program
setup
ENABLE SMART
RECOVERY? NO
49.
clock
setup
SET TIME & DAY:
12:00 AM MON
2.
override
SET DATE:
11-19-01
clock
setup
3.
MON
11-19-01
12:00AM
72F
clock
setup
ENTER ACCESS
CODE 000
1.
SET OCCUPIED
TIMES MONDAY:
clock
setup
4.
Smart Recovery Screen.
Choose
whether or not smart recovery will be
used.
Note: Smart Recovery is not avail-
able when DI3 is used as EXTernal TIME
CLOCK.
Programming Access Screen.
Choose
whether or not a code will be required
to enter programming setup. A dipswitch
option to lock out access altogether is also
available.
Clock and Schedule Access Screen.
Choose whether or not a code will be
required to enter clock and schedule
setup. A dipswitch option to lock out
access altogether is also available.
Access Code Screen.
Enter a second-
ary access (0 to 255) code that will be
used to enter the programming and/or
clock and schedule setups if access code
has been required in the last two steps.
This code can be given to your customer
and can be changed later. The primary
code is 248, it always works and cannot
be changed