TCL U-MATCH-R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL
205
Cautions:
●
Please contact the nearest after-sale service center when maintenance is necessary. At the time
of maintenance, the maintenance personnel must strictly comply with the Operation Manual provided
by the corresponding manufacturer and any non-professional is prohibited to maintain the air
conditioner.
●
It is necessary to comply with the provisions of gas-related national laws and regulations.
●
It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air
conditioner.
●
When filling the combustible refrigerant, any of your rude operations may cause serious injury
or injuries to human body or bodies and object or objects.
●
A leak test must be done after the installation is completed.
●
It is a must to do the safety inspection before maintaining or repairing an air conditioner using
combustible refrigerant in order to ensure that the fire risk is reduced to minimum.
1
)
Installation Safety
Installation Safety Principles
Site Safety
Open Flames Prohibited
Ventilation Necessary
Operation Safety
Mind Static Electricity
Must wear protective clothing and anti-static gloves
Don`t use mobile phone
Installation Safety
Caution:
●
The installation should be in a well-ventilated condition location.
●
When you installing or maintaining an air conditioner using Refrigerant R32, the location
should be free fire from open or any other goods temperature higher than 548
℃
for R32 which easily
produces open fire include welding, smoking, drying oven.
●
When installing an air conditioner of R32, it is necessary to take appropriate anti-static measures
such as wear anti-static clothing and gloves.
●
It is necessary to choose the location for installation or maintenance where in the air inlets and
outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any heat
source or combustible and/or explosive environment.
●
If the indoor unit suffers refrigerant leak during the installation, it is necessary to immediately turn
off the valve of the outdoor unit and all the personnel should go out till the refrigerant leaks
completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product
back to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other
operations on
the user’s site.
●
It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
●
It is necessary to avoid the places where there are other electrical products, power switch plugs
⚫
Refrigerant Leak Detector
⚫
Appropriate Installation
Location
The left picture is the schematic diagram of a refrigerant leak
detector.
Содержание U-MATCH-R32 Series
Страница 1: ...TCL U MATCH R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL...
Страница 21: ...TCL U MATCH R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL 20 30K 36K...
Страница 22: ...TCL U MATCH R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL 21 42 48K 55K...
Страница 28: ...29 TCL U MATCH R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL 36K 55K Body dimension 840X290X840...
Страница 32: ...32...
Страница 40: ...40 TCL U MATCH R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL 36K 42K 48K 55K Three phases unit...
Страница 43: ...43 TCL U MATCH R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL 36K 42K 48 55K three phase models...
Страница 90: ...TCL U MATCH R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL 205 Ceiling Floor Type Unit 1 phase 12k 30 k...
Страница 91: ...TCL U MATCH R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL 205 Ceiling Floor Type Unit 1 phase 36k...